INSTALLER’S GUIDE
Page 44
Figure 59. Front surround top
location
Figure 58. Control linkage
disconnection
Figure 57. Front Surround
Bottom Location
2.
Detach the microswitch cover by removing one
screw and pulling clear of the location lug. See figure
54.
3.
Loosen the thermocouple nut to free the
microswitch leads and pull the leads clear of the
thermocouple interrupter block. See figure 56.
4.
Detach the bridging bracket, microswitch assembly
and insulation pad by removing two screws. See figure
55.
5.
Replace in the reverse order. When refitting the
leads to the interrupter block, make sure that they are
secured firmly to give a good electrical contact.
16.4
To Remove the Fire Front Surround
1.
Remove the bottom front cover and the fire
front casting.
2.
Detach the control-linking bar from the
control pivot bracket by removing the knurled
screw, which joins the control linking bar to the
control pivot unit. See figure 58.
3.
Remove the two screws securing the bottom
of the front surround to the sides of the
convection box. See figure 58.
4.
Make sure that the control linking bar has
been detached (See 2 above)
.
Carefully lift the
surround unit upward to clear the upper
retaining brackets on the convection box - See
figure 59. Pull the surround clear and place
carefully aside.
5.
Refit in the reverse order. Make sure that the
surround is properly located over the upper
retaining brackets. See section 11 of this manual
for detailed fitting instructions.
16.5
To Replace the Control Slide Unit
1.
Remove the front surround - See section 16.3.
2.
Detach the slide unit by removing two screws
securing the plastic slide mechanism to the rear of the front surround – See figure 59.
3.
Replace in the reverse order.