background image

We recommend that our gas 

hearth products be installed 

and serviced by professionals 

who are certified in the United 

States by NFI (National Fireplace 

Institute

®

).

Thank You ...

For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical 

appliance that must be installed by a qualified dealer. Each Valor fireplace is fully 

tested during the production process for your safety and comfort.

Your unit has been professionally installed by:

Dealer Name  _______________________________________

Phone Number  ______________________________________

Should you encounter an operational problem, call your dealer immediately.

Do not try to repair the unit as you may cause an injury or damage the fireplace

.

The information contained in this installation manual is believed to be correct at 

the time of printing. Miles Industries Ltd. reserves the right to change or modify any 

information or specifications without notice. Miles Industries Ltd. grants no warranty, 

implied or stated, for the installation or maintenance of your heater, and assumes no 

responsibility for any consequential damage(s).

Designed and Manufactured by / for

Miles Industries Ltd.

 190–2255 Dollarton Highway, North Vancouver, BC, CANADA  V7H 3B1

Tel. 604-984-3496  Fax 604-984-0246

www.valorfireplaces.com

© Copyright Miles Industries Ltd., 2010

Do not put 

furniture or other objects 

in this space in front of 

the fireplace:

36” (0.9 m)

Fireplace

Hearth

2

Содержание 785ILN

Страница 1: ...domestic room heating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES...

Страница 2: ...l your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time o...

Страница 3: ...einstall 15 Ceramic Panels Installation 15 Ceramic Logs Installation 16 Window Refitting 18 Remote Control Initial Set up 19 Operation Check Aeration Settings Adjustment 20 Side Shrouds Installation 2...

Страница 4: ...ration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the applian...

Страница 5: ...rdance with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas utility to confirm For insta...

Страница 6: ...appliance is NOT APPROVED for installation with a zero clearance kit 785IL fireplace Chimney Terminal Cap Flashing 2 x 3 approved flex chimney liners running full length Existing unaltered functioning...

Страница 7: ...fan power cord outlet 6 1 9 m Fan power cord Trim sold separately Valve access panel X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is...

Страница 8: ...ls that bear the UL mark for zero 0 fire rating Sidewall Clearances Minimum distance from side of appliance liner box to combustible wall 9 229 mm Mantel Projection A 1 25 mm 4 101 mm 8 203 mm 14 355...

Страница 9: ...rbed airflow hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination M...

Страница 10: ...inserting the 785IL into an existing fireplace cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existing fireplace Components that are...

Страница 11: ...ccess hole of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See D...

Страница 12: ...e installed before the appliance is fitted into the cavity Refer to instructions provided with the 795CFK to install the fan Window Removal The window is held in place by a spring loaded lever on each...

Страница 13: ...owards the back of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure wi...

Страница 14: ...g its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance...

Страница 15: ...Rotate the anchor back down to hold the panel The ceramic panels can be installed without removing the burner However you can remove the burner for additional space if desired 1 Remove the 2 screws f...

Страница 16: ...ating its right hand end over the key in the ember bed Slide the log back until it rests against the vertical sheet metal edge 2 Place the left hand middle log in front of the rear log locating it ove...

Страница 17: ...e the right hand base log locating its notch on the key in the ember bed as indicated 6 Place the right hand middle log locating its notch on the key in the ember bed as indicated 7 Place the left han...

Страница 18: ...and release it to ensure the springs return it 4 Apply light hand pressure against the window frame sides to bed in the window seal Window frame Bottom railing Ceramic Logs Installation 8 Place the r...

Страница 19: ...x Place the battery box upside on the left of the firebox Battery box connection Reset button Battery box Remove cover Connect battery box to wire 5 With a sharp object press and hold the receiver s r...

Страница 20: ...low the unit to warm up for 10 15 minutes to evaluate the flame picture Burners are equipped with an adjustable shutter to control primary aeration See the figures below The shutters are factory set t...

Страница 21: ...th the kit See the diagram below for required hardware and configurations Note that the holder can be installed at the base of a light switch plate IMPORTANT The location of the remote control handset...

Страница 22: ...ength of the glass An emulsion type cleaner is recommended Use a soft damp cloth to apply the cleaner Dry the glass with a soft dry preferably cotton cloth Most paper towels and synthetic materials ar...

Страница 23: ...and one 9 V alkaline battery for its handset Batteries should last one to two seasons depending on usage Removing the batteries in the off season will extend the battery life Should the batteries loo...

Страница 24: ...from the remote handset and turn off the gas valve using the manual ON OFF switch Pilot Automatic Shut off The remote control system is equipped with safety features allowing it to shut the fire down...

Страница 25: ...ng your fireplace OFF 1 Press the small flame button to reduce the flame to pilot 2 Press the OFF button to turn the pilot off Alternately you can press the O button on the switch if you won t use you...

Страница 26: ...ically adjusted to achieve the Daytime set temperature temp TEMP MODE Nighttime Setback Temperature Mode appliance must be in Standby mode pilot ignited The room temperature is measured and compared t...

Страница 27: ...perature control to turn off decrease the temp MODE setting until appears on the display Your fireplace will reach the set temperatures and the remote handset will check the temperature every five min...

Страница 28: ...hen briefly press SET to P1 and set the stop time in the same manner you just set P1 4 Briefly press the SET button again for the next burner cycle time which will be P2 and P2 5 Once all four times a...

Страница 29: ...etail stores carrying safety products for children Automatic Turn Down No communication If there is no transmission from the handset to the receiver within a 6 hour period the appliance will go to Sta...

Страница 30: ...f you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION g 1 Locate the pilot g 3 inside of rebox at Left Hand side O...

Страница 31: ...Wiring Diagram Remote Battery Box Optional Fan 795CFK Control Module Optional Wall Switch Kit 1265WSK Latching Solenoid Valve Red Yellow 4 AA Batteries GV60 Wiring Diagram Connector 31...

Страница 32: ...nector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA Co linear to Co axial Adapter 46DVA GK TM 4CTA Aluminum Flexible Liner 3 diameter 2280 Series 3 ACFL NOTE 2 ply liner approved to CAN U...

Страница 33: ...or air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cove...

Страница 34: ...le 4000061 34 Pilot Injector 51 NG 4000735 Pilot Injector 30 LPG 4000736 35 Pilot Tube 4000732 36 Pilot Hood 2 Flame 4000730 37 Extended Nut 4001855 Code Description Part Number 38 Electrode 4001856 3...

Страница 35: ...Left side panel a Ledgestone 4002365 b Enamel black 4002371EB c Ceramic fluted black 4002377 d Valor red brick 4002382 64 Right side panel a Ledgestone 4002366 b Enamel black 4002372EB c Ceramic flute...

Страница 36: ...Spare Parts 43 44 45 46 47 48 49 50 60 61 62 63 64 51 58 59 57 56 55 54 53 52 1 2 3 7 8 9 10 12 14 15 13 11 16 24 23 25 26 26a 17 18 19 19 21 22 20 32 38 42 F R 40 41 27 28 30 29 31 9 39 36...

Страница 37: ...NG natural gas LPG propane Serial No Front Trim code description e g 790FTV Floating Trim Kit Vintage Iron Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone E...

Страница 38: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: