A
B
Do not put
furniture or
objects within
36” (914 mm)
of the front of
appliance
Sidewall Clearances
Minimum
distance from side of appliance (liner box) to
combustible wall: 9” (229 mm).
Mantel legs projecting forward less than 6” (152 mm)
may be located within 5” (127 mm) of the side of the
appliance (liner box).
Floor/Hearth Clearances
Combustible shims/supports may be used beneath
the appliance to level or raise the appliance within the
existing fi replace cavity.
Combustible fl ooring/hearths in front of the appliance
are allowed provided they are no higher than the
base of the appliance (note—may be subject to local
authority approval).
9” (229 mm)
sidewall
WARNING
Some materials or items, although safe, may discolor, shrink, warp, crack, peel,
and so on because of the heat produced by the fi replace. Avoid placing candles,
paintings, photos, and other items sensitive to heat around the fi replace.
Combustible Mantel Clearances
*Measure taken from the underside of the mantel to fi nished
hearth or surface that the unit is sitting on.
Finishing Materials
Combustible materials:
Material such as wood,
compressed paper, plant fi bers, plastics or any material
capable of igniting and burning, whether fl ame-proofed
or not, plastered or un-plastered.
Non-combustible materials:
Material such as steel,
iron brick, tile, concrete or materials that bear the UL
mark for zero (0) fi re rating.
WARNING
HOT GLASS!
The use of a screen in front of
the glass is highly recommended particularly in
households with children.
WARNING
HOT HEARTH / FLOOR!
The hearth or fl oor in
front of the fi replace may become very hot when
the fi replace heats. Do not use the hearth as a seat
or shelf. Solid wood fl ooring in front of the fi replace
(if allowed) may shrink during the heating season
due to heat.
WARNING
!
WARNING
!
WARNING
!
Mantel Pro-
jection A
1”
(25 mm)
1”– 6”
(25–152 mm)
9”
(229 mm)
12”
(305 mm)
Mantel
Height B*
36”
(914 mm)
39”
(991 mm)
42”
(1067 mm)
45”
(1143 mm)
QUALIFIED
INSTALLER
17
Clearances