Safety Precautions

!

Children and adults should be 

ALERTED

 to the hazards 

of high surface temperature and should 

STAY AWAY

 to 

avoid burns or clothing ignition.

YOUNG CHILDREN

 should be 

CAREFULLY

 

SUPERVISED

 when they are in the same room as the 

appliance. Toddlers, young children and others may 
be susceptible to 

ACCIDENTAL CONTACT BURNS

A physical barrier is recommended if there are at-risk 
individuals in the house. To restrict access to a fi replace 
or stove, 

INSTALL AN ADJUSTABLE SAFETY GATE

 

to keep toddlers, young children and other at-risk 
individuals out of the room and away from hot surfaces.

DO NOT 

place furniture or any other combustible 

household objects within 36” of the fi replace front.

READ

 and 

UNDERSTAND

 all instructions carefully 

before starting the installation. 

FAILURE TO FOLLOW

 

these installation instructions may result in possible fi re 
hazard and will void the warranty.
Prior to the fi rst fi ring of the fi replace, 

READ

 the 

Owner’s Information section of this manual.

DO NOT USE 

this appliance if any part has been under 

water. Immediately, 

CALL

 a qualifi ed service technician 

to inspect the unit and to replace any part of the control 
system and any gas control that has been under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED

 by a 

qualifi ed service person. The appliance and venting 
system should be 

INSPECTED

 before initial use and at 

least annually by a professional service person. More 
frequent cleaning may be required due to excessive 
lint from carpeting, bedding, etc. It is 

IMPERATIVE

 that 

the unit’s control compartment, burner, and circulating 
air passageways 

BE KEPT CLEAN 

to provide for 

adequate combustion and ventilation air.
Always 

KEEP

 the appliance clear and free from 

combustible materials, gasoline, and other fl ammable 
vapors and liquids.

NEVER OBSTRUCT 

the fl ow of combustion and 

ventilation air. Keep the front of the appliance 

CLEAR

 

of all obstacles and materials for servicing and proper 
operation.

Due to the high temperature, the appliance should be 

LOCATED

 out of traffi  c areas and away from furniture 

and draperies.
Clothing or fl ammable material 

SHOULD NOT BE 

PLACED 

on or near the appliance.

This unit 

MUST

 be used with a vent system as 

described in this installation manual. 

NO

 

OTHER

 vent 

system or components 

MAY BE USED

.

This gas fi replace and vent assembly 

MUST

 be vented 

directly to the outside and 

MUST

 

NEVER

 be attached 

to a chimney serving a separate solid fuel burning 
appliance. Each gas appliance 

MUST USE 

a separate 

vent system. Common vent systems are 

PROHIBITED

.

INSPECT

 the external vent cap on a regular basis to 

make sure that no debris, plants, trees, shrubs are 
interfering with the air fl ow.

DO NOT OPERATE

 this appliance with the glass door 

removed, cracked, or broken. Replacement of the glass 
door should be performed by a licensed or qualifi ed 
service person. 

DO NOT

 strike or slam the glass door.

The glass door assembly 

SHALL ONLY 

be replaced 

as a complete unit, as supplied by the fi replace 
manufacturer. 

NO SUBSTITUTE

 material may be used.

BARRIER DESIGNED TO REDUCE THE RISK OF 

BURNS

 from the hot viewing glass is provided with 

this appliance and 

SHALL BE INSTALLED

 for the 

PROTECTION OF CHILDREN

 and other 

AT-RISK 

INDIVIDUALS

.

DO NOT USE 

abrasive cleaners on the glass door 

assembly. 

DO NOT ATTEMPT

 to clean the glass door 

when it is hot.

If the barrier becomes damaged, the barrier 

SHALL BE 

REPLACED

 with the 

MANUFACTURER’S BARRIER

 

for this appliance.

TURN OFF

 the gas before servicing this appliance. 

It is recommended that a qualifi ed service technician 
perform an appliance check-up at the beginning of each 
heating season.

Any safety screen, guard or barrier removed for ser-
vicing the appliance, 

MUST BE REPLACED 

prior to 

operating the appliance.

BE CAREFUL

 not to put any decorating objects 

sensitive to heat to close above or around the fi replace 
as it gets very hot when operating.

DO NOT 

use this heater as a temporary source of heat 

during construction.

This appliance is a 

DOMESTIC ROOM-HEATING AP-

PLIANCE

. It must not be used for any other purposes 

such as drying clothes, etc.

State of California. Proposition 65 Warning. 

Fuels 

used in gas, wood-burning or oil fi red appliances, 
and the products of combustion of such fuels, contain 
chemicals known to the State of California to cause 
cancer, birth defects and other reproductive harm. 
California Health & Safety Code Sec. 25249.6.

The glass door assembly 

MUST

 be in place and sealed 

before the unit can be placed into safe operation.

Содержание 739-72ILN/P

Страница 1: ...s appliance is not convertible for use with other gases unless a certified kit is used This appliance is a domestic room heating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room This appliance may be installed in an after market permanently located manufactured mobile home where not prohibite...

Страница 2: ... Check Operation 27 Adjust Aeration if necessary 27 Install Handset Wall Holder 27 Install Front and Barrier Screen 28 Approved Venting Components 29 Warranty 30 Spare Parts 31 2 Table of Content Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www valorfireplaces com Copyright Miles Industries Ltd 2...

Страница 3: ...E PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance Each gas appliance MUST USE a separate vent system Common vent systems ar...

Страница 4: ...ce A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk individuals a safe distance from the fireplace Keep the remote control handset out of reach of children at all times A wall mount storage holster is provided with your remote control handset Ensur...

Страница 5: ...stible materials and although safe it may reach temperatures in excess of 200º F depending on choice of materials DO NOT STEP ON IT Some materials or items although safe may Some materials or items although safe may discolor shrink warp crack peel and so on discolor shrink warp crack peel and so on because of the heat produced by the fireplace because of the heat produced by the fireplace AVOID PLAC...

Страница 6: ...ual Inspect primary air openings for blockage see Checking Pilot and Burner Flame section of this manual 5 Inspect condition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure response time of the flame safety system It must de energize the safety shutoff in no mo...

Страница 7: ...cts B P P byK C T C C by E W O by R T W Do not clean the glass while it is hot Always securely replace the window and the barrier screen before lighting If broken the glass pane may only be replaced as a complete window unit as supplied by the manufacturer If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance To remove the window for cleani...

Страница 8: ...battery life Should the batteries loose power the control may be operated by manually turning the control knob at the valve or by turning off the valve at the switch Hot Glass Plate WARNING FOR SAFETY PURPOSE ensure the barrier screen is re installed on the fireplace front after maintenance CAUTION DO NOT USE a screwdriver or other metallic object to remove the batteries from the receiver or the han...

Страница 9: ...ery year see page 6 Contact your supplier quoting the model number It will be helpful if the appliance s serial number can also be quoted This number is on the rating plate which is located under the burner The replacement parts are shown at the end of this manual Please always quote the part number and description when requesting spare parts Turn gas valve buttons clockwise to turn fireplace OFF F...

Страница 10: ... the temperature hour display press on the AUTO button while the display flashes 4 Let go and wait until the flashing stops The remote shows the time you set It also shows the current temperature Setting the temperature Use this setting when you come in and want to enjoy a specific temperature 1 Push the AUTO button until a number and F flash Let go 2 While it is still flashing push the and buttons to ...

Страница 11: ...ou want your fireplace to turn off when you leave 5 Press the TIMER button and hold it until P2 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace will turn back on in the afternoon 6 Press the TIMER button and hold it until P2 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you ...

Страница 12: ... 755CFK Fan Kit 759EBL Enamel Liners 760CBL Ceramic Black Fluted Liners 4001515 Valor Red brick set Conversion Kit 739PGK Conversion Kit to Propane Gas 739NGK Conversion Kit to Natural Gas Hearth Gate Hearth gates such as Cardinal s VersaGates are available at retail stores carrying safety products for children Information accurate at the time of printing and subject to change without notice 12 OW...

Страница 13: ...n above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force 4 Wait five 5 minutes to clear out any gas then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next ste...

Страница 14: ...et 1 370 m in USA installations must be in accordance with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas utility to confirm For installations at elevations above 4 500 feet 1 370 m in Canada please consult provincial and or local authorities having jurisdiction Supply Gas Heater engine ...

Страница 15: ...separately Inner Front with Barrier Screen included 2 x 3 approved flex chimney liners running full length WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may become very hot when the fireplace heats Do not use the hearth as a seat or shelf Solid wood flooring in front of the fireplace if allowed may shrink during the heating season due to heat WARNING Some materials or items alth...

Страница 16: ...l Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clearances for allowable clearances Minimum width of fireplace opening at front 28 711 mm X 12 14 305 357 mm varies with outer trim options Y 20 508 mm 24 610 mm when using 763 Backing Plate QUALIFIED INSTALLER 16 ...

Страница 17: ...at around the fireplace Combustible Mantel Clearances Measure taken from the underside of the mantel to finished hearth or surface that the unit is sitting on Finishing Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non combustible materials Material such...

Страница 18: ...ermination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to center of pipe Maximum offset angle 45 sweeping bend to allow for obstructions Venting Notes Where possible avoid joining flex pipes If joints are required use a approved connector and seal joints with ...

Страница 19: ... appliance 3 Check that you have everything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing fireplace 7 Install and test fan blower if used 8 Fit appliance into cavity 9 Connect and test gas supply 10 Install ceramic liners if used 11 Install logs Existing Dampers Factory built zero clearance fireplaces will require the damper to be removed...

Страница 20: ...om of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions section for detailed location of gas inlet Also take into consideration whether or not a fan or shut off valve will interfere when planning routing of the gas line Existing Glass Doors and Wire Screens Existing glass doors must be permanently removed prior to ...

Страница 21: ...side in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the firebox to facilitate its installation If the fan is retrofitted after the installation of the appliance the burner module will need to be removed Therefore we recommend that where possible the fan be inst...

Страница 22: ...ack of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping screws per liner If the vent slider was removed from the firebox slide the firebox onto the vent slider in the cavity taking care not to damage the liners Make sure that the rear edge of the slider is hoo...

Страница 23: ...est pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during pressure testing may resulting regulator or valve damages and void the warr...

Страница 24: ...est cross log Both front logs to rest slightly on the edge of the firebox window frame Center the front logs side to side in relation to the firebox Place it on the right pin located on the rear log Rest its other end in the crook of the front right log 5 Identify the middle cross log It does not have a hole underneath Place its narrow end on the flat depression in the rear log next to the right cros...

Страница 25: ...orrectly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covered by the Valor warranty DANGER The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the appliance may result To ensure a safe op...

Страница 26: ...ve the batteries from the receiver or the handset This could cause a short circuit to the receiver CAUTION DO NOT PUT BATTERIES IN THE REMOTE CONTROL RECEIVER until the wires are con nected to the burner control unit as short circuit could result in the destruction of the electrical components 3 Remove the remote control receiver lid 4 Fit four AA 1 5 V alkaline batteries Refit the lid 5 Place the ...

Страница 27: ...should be located away from any other heat source and not in direct sunlight as this may affect the temperature sensor located in the remote handset Installation Check Operation Turn the fireplace flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 10 11 Adjust Aeration if necessary Light the fire and all...

Страница 28: ... with the heater The Contemporary Front is equipped with a barrier screen The barrier screen is designed specifically to prevent any contact with the glass of the fireplace which becomes hot during operation and remains hot when cooling Installation 1 Install the outer surround to the engine according to the installation instructions provided with the surround 739 72 Trim Matt Black Front Overview t...

Страница 29: ...Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and others 2280 Series AF3 35L 952703 952704 Flashings Roof Flashing 0 12 6 12 46DVA F6 4DT AF6 TF 4FA SV4FA 4DF 0 12 5 12 949606012 Roof Flashing 7 12 12 12 46DVA F12 4DT AF12 TF 4FB SV4B 4DF12 6 12 12 ...

Страница 30: ...damage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass log breakage or damage to the unit while in transit j The Comp...

Страница 31: ...Hooked Olive for Pilot Injector 720A196 22 Olive Nut for Pilot Pipe 420K385 23 Electrode 720A543 24 Electrode Retaining Nut 720A200 25 Thermocouple 4000061 26 Pilot Gasket A 4000139 27 Pilot Mount 4000138 28 Pilot Gasket B 4000140 29 Burner Tray 4001676 30 Pipe Valve to Main Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gasket Right 400...

Страница 32: ...ane gas 18 20 25 21 22 23 24 19 43 44 45 1 2 3 4 5 6 7 8 46 49 48 47 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 42 40a 40b 14a Natural gas Propane gas 13a 41 50 51 52 53 54 55 49 47 32 OWNER S INFORMATION ...

Страница 33: ...on provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model Number 739 72ILN 739 72ILP Serial Number Date Purchase yyyy mm dd Dealer Customer Information First Name Last Name Contact Information Email Mailing Address Address City Province State Postal Zip Code Cou...

Страница 34: ... Shut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplaces com ...