![Valor 739-72ILN/P Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/valor/739-72iln-p/739-72iln-p_installation-and-owners-manual_851501006.webp)
Owner’s Information
1. Inspect and operate the pressure relief mechanism to verify relief mechanisms are free from obstruction
to operate—see
Cleaning Your Fireplace: To re
fi
t the window
section of this manual.
2. Clean glass window with a suitable fi replace glass cleaner. Abrasive cleaners must not be used. Be
careful not to scratch the glass when cleaning—see
Cleaning Your Fireplace
section of this manual.
3. Inspect the operation of the fl ame safety system Pilot or Flame rectifi cation device.
4. Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve
opening. Visual inspection should match that outlined in the appliance instruction manual. Inspect
primary air openings for blockage—see
Checking Pilot and Burner Flame
section of this manual.
5. Inspect condition of vent and vent terminal for sooting or obstruction and correct if present.
6. Vacuum and clean any debris in the fi rebox that is not supposed to be there.
7. Test and measure the fl ame failure response time of the fl ame safety system. It must de-energize the
safety shutoff in no more than 30 seconds.
8. Check all accessible gas-carrying tubes, connections, pipes and other components for leaks—see
Set up
Gas Supply
section of this manual.
Annual Inspection
In order to maintain the safe operation of your fi replace,
contact your dealer to have a qualifi ed technician go
over the list below and make the necessary verifi cations
at least once every year.
Annual Inspection List for a Safe Operation—to be performed by a qualifi ed technicien only
6