FOR YOUR SAFETY READ BEFORE LIGHTING

 

 

WARNING:

 If you do not follow these instructions exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life.  
A.  This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow these 
instructions exactly. 
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor 

because some gas is heavier than air and will settle on the floor. 

WHAT TO DO IF YOU SMELL GAS 

 

Do not try to light any appliance. 

 

Do not touch any electric switch; do not use any phone in your building. 

 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

 

If you cannot reach your gas supplier, call the fire department. 

C. Use only your hand to push in or turn the control knobs. Never use tools. If the controls will not push in 

or turn by hand, don’t try to repair them, call a qualified service technician. Force or attempted repair 
may result in a fire or explosion. 

D. Do not use this appliance if any part has been under water. Immediately call a qualified service 

technician to inspect the appliance and to replace any part of the control system and any gas control, 
which has been under water. 

 

LIGHTING INSTRUCTIONS 

 

1.  STOP!  Read the safety information above. 

2.  Set the flame adjustment knob as 

far clockwise 

as possible

*

3.  Turn the gas control knob clockwise 

 to OFF. 

NOTE: The knob cannot be turned from PILOT to OFF 
unless it is pushed in partially. Do not force. 
4.  Wait five (5) minutes to clear out any gas, then smell 

for gas, including near the floor. If you smell gas, 
STOP! Follow “B” in the safety information above. If 
you don’t smell gas, go to the next step. 

5.

 

Find the pilot. It is at the left side of the firebox 
viewed through hole in front log. 

6.  Push in and turn the gas control knob counterclockwise        until resistance is felt just before the 

“IGN” position. 

7.  Keep pushed in for a few seconds to allow gas to flow then, keeping knob depressed, turn to “PILOT” 

to light pilot. Hold knob in for a further 5 seconds then release. The knob should pop back out. Pilot 
should remain lit. If pilot goes out repeat steps 3 through 7. 

 

If knob does not pop out when released, stop and immediately call your service technician or gas 
supplier. 

 

If pilot lights but will not stay lit after several tries, turn the gas control knob to “OFF” and call 
your service technician or gas supplier. 

8. 

When pilot is lit, partially depress the knob and turn to “ON” position (Burner alight). 

 

 

Do not leave knob set between “PILOT” and “ON”. 

9. 

Set the flame height to desired setting

*

 

TO TURN OFF GAS TO APPLIANCE 

 

1. 

Set the flame adjustment knob as far clockwise                as possible

*

 

 
2. 

Push in gas control knob slightly and turn clockwise              to “OFF”. Do not force. 

 

*

 The flame height can be increased or decreased by depressing the remote control hand set button.

Flame 
Adjustment 
Knob 

Содержание 530SAN

Страница 1: ...ith the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appliance is a domestic room heating appliance It must...

Страница 2: ...op Insulation Layers ZC Models only 29 8 11 Appliance Wall or Floor Fixing President FS only 29 9 INSTALLATIONS WITH HORIZONTAL TERMINATION INSTALLING TO WALL 30 9 1 Installations except with Valor 55...

Страница 3: ...combustible materials gasoline and other flammable vapors and liquids Never attempt to burn paper or any other material in the appliance The venting terminal must not be recessed into a wall or sidin...

Страница 4: ...t 817VAK Adapter for Dura vent pipes 984 Dura vent DV GS horizontal square terminal cap 942 Dura vent DV GS wall thimble kit 945B 45 Dura vent DV GS elbow 990B 90 Dura vent DV GS elbow 908B 6 Dura ven...

Страница 5: ...Up to 5 4 Above 5 up to 7 5 Above 7 up to 8 7 Above 8 up to 9 8 Above 9 up to 12 10 More than 12 10 extra 1 for every 1 depth above 12 Mantle leg projection D Min clearance from appliance side E Up to...

Страница 6: ...d must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 3 2 Ratings Nat...

Страница 7: ...th of the appliance 4 2 Venting configurations 4 2 1 Flat on wall Requires Valor vent kit 551DVK or Dura vent pipe length with adapter 817VAK and Dura vent terminal cap The location requirements are s...

Страница 8: ...3 3cm H Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16in 3 3cm 4 2 4 Rear vent connection vertical vent rise with horizontal snorkel terminat...

Страница 9: ...90 vent elbow 990B Dura vent pipe lengths a vertical vent terminal and roof flashing will be required Various other ceiling or roof items may be necessary depending on the particular installation See...

Страница 10: ...ace and chimney The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Requires adapter 817VAK Co axial to co linear connector 923GCL two lengths of Chim...

Страница 11: ...o combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16in 3 3cm 4 2 11 Top vent connection vertical vent rise with horizontal side termination Figs 13 14 Can be u...

Страница 12: ...ight horizontal termination Figs 13 16 Can be used with either 551DVK standard vent kit or 984 Dura vent terminal cap and accessories Adapter 817VAK one 90 elbow 990B and Dura vent pipe lengths will b...

Страница 13: ...ry in an attic to avoid obstructions or allow useful space Adapter 817VAK two 45 vent elbows 984 wall straps a vertical vent terminal roof flashing and Dura vent pipe lengths will be required Various...

Страница 14: ...tudding see figure 21 This enables a variety of wall finish thicknesses to blend with the appliance surround A non combustible hearth is not necessary in front of this appliance Any framing constructi...

Страница 15: ...use of any vent accessory pipes 5 2 2 Flat on wall with snorkel termination Fig 23 For use on horizontal vent installations where the outside ground level is too close to the standard terminal Adapte...

Страница 16: ...mbustible materials below horizontal pipe run 15 16 3 3cm H Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16 3 3cm 5 2 4 Rear vent connection ve...

Страница 17: ...e 90 vent elbow 990B Dura vent pipe lengths a vertical vent terminal and roof flashing will be required Various other ceiling or roof items may be necessary depending on the particular installation Se...

Страница 18: ...pe run 15 16 3 3cm H Clearance to combustible materials all round vertical pipe run and at sides of horizontal pipe run 15 16 3 3cm 5 2 10 Top vent connection vertical vent rise with horizontal side t...

Страница 19: ...See venting section of this manual All vertical dimensions and clearance limits are as section 5 2 9 The minimum corner location is shown in fig 31 5 2 13 Top vent connection vertical vent rise throug...

Страница 20: ...ry in an attic to avoid obstructions or allow useful space Adapter 817VAK four 45 vent elbows 984 wall straps a vertical vent terminal roof flashing and Dura vent pipe lengths will be required Various...

Страница 21: ...ensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Clearance to unv...

Страница 22: ...coals 4 Wood screws 4 Wall plugs 2 Thread cutting screws 1 Deluxe remote control kit 531CSB President free standing case Alternative Top pack 1 Top casting 1 Top infill plate Sides pack 1 Front casti...

Страница 23: ...uring the bottom of the window See figure 35 3 Carefully lift the window Keep the window and bolts in a safe place 8 2 Check ignition spark The pilot burner and electrode unit is at the left end of th...

Страница 24: ...crewing 8 screws See figure 37 4 To make sure that the collars are axially aligned fit the Dura vent adapter 817VAK over the outer vent collar See figure 38 5 Position the inner collar and seal vertic...

Страница 25: ...e the adapter to the outer collar with two 6 thread cutting screws supplied Fig 39 8 4 2 For Installations With Dura Vent DV GS Co Linear Liners 1 Fit the Dura vent adapter 817VAK over the appliance v...

Страница 26: ...are left and right handed Warning Failure to install the stand off spacers may result in a fire hazard 1 Remove the two screws near each of the rear top corners of the appliance and the two screws nea...

Страница 27: ...n in the table below To fit the restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom sc...

Страница 28: ...cutting screws supplied Screw from outside through the access holes in the surround See figure 49 3 The outer surround has alternative locating tabs allowing its front face to be positioned 1 2 or 1 i...

Страница 29: ...zard and voids warranty 8 11 Appliance Wall or Floor Fixing President FS only The President FS can be secured to the wall and or floor if required The fixing positions are shown in figure 4 Holes shou...

Страница 30: ...ne up with the centerline of the horizontal vent 9 3 Flat On Wall Installations With Valor 551DVK Terminal 1 Cut the vent terminal pipe unit to size Fig 51 Important The drain hole must be clearly out...

Страница 31: ...the wall with 4 screws provided 9 4 1 Installing Appliance to Wall 1 Slide the appliance fully up to the wall 2 Bend the outer wall plate tab as shown in figure 53 Place the outer wall plate over the...

Страница 32: ...p must be installed at the second floor and higher floors A ceiling support should be used below the flat ceiling To install the firestop support cut and frame a 10 254mm square hole centered on the s...

Страница 33: ...p and slot in the board is inline with the tab on the wiring harness plug Connect wires A with the L terminals to the connectors B on the control valve Please note that the connectors are different si...

Страница 34: ...in the line The tapping must be accessible for test gauge connection and be immediately upstream of the gas supply connection to the appliance 7 Pressure test the supply line for leaks The appliance...

Страница 35: ...fects and window installed See the Final checks section in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance...

Страница 36: ...ront of the firebox See figure 66 4 Place the right side log in the hollow at right of the base log Rest the narrow nose of this log on the projection at front center of the base log It is important t...

Страница 37: ...be near the middle front of the firebox See figure 70 3 Place the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coa...

Страница 38: ...appliance and all other controls appliance rocker switch wall switch remote hand unit See owner s lighting instructions further on in this manual for full details 2 Aeration adjustment As described i...

Страница 39: ...in figure 77 2 Fit the top casting making sure that the corners locate as shown in figure 78 3 If rear vent connection Fit the top infill casting See figure 79 4 If necessary the appliance can be leve...

Страница 40: ...ront unit the top of the front can be moved forward to allow the tiling to go behind the top To move the top slacken the clamping bolts slide the top forward retighten the bolts See figure 81 2 Hang t...

Страница 41: ...se this setting when you want a particular flame level For instance you want to watch flames burn at their highest level and you don t mind if the room is too hot Here s what you do a Press either of...

Страница 42: ...ront unit See figure 83 President ZC Unhook the front unit Lift the front by holding the decorative grille Don t lift by holding the top See figure 84 Opening the window See figure 85 Always securely...

Страница 43: ...ob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force 4 Wait five 5 minutes to cle...

Страница 44: ...AA batteries for thermostat control For Appliances with Rocker Switch on Side or Surround the batteries are accessible by opening the bottom access panel For Appliances with Wall switch the batteries...