31
9.4.
Preparing Wall Plates
The wall plates are not used for 7” hole in non-combustible walls.
1.
Bend the wall shields and screw to the inside of the wall plates with 6 thread cutting
screws per plate. see figure 52.
2.
Bend the inner wall plate tab as shown in figure 53 so that the seam on the terminal
tube will pass clearly through the plate with the wall shield at the top. Place the inner wall
plate over the terminal unit. Slide the appliance towards the wall so that the terminal
enters the wall. Slide the inner wall plate up to the wall. Mark the four holes for the wall
screws. Slide the plate away.
3.
Drill and plug the wall.
4.
Screw the plate to the wall with 4 screws provided.
9.4.1.
Installing Appliance to Wall.
1.
Slide the appliance fully up to the wall.
2.
Bend the outer wall plate tab as shown in figure 53. Place the outer wall plate over
the terminal unit. Slide the wall plate up to the wall. Mark the four holes for the wall screws. Slide the plate away.
3.
Drill and plug the wall.
4.
Screw the plate to the wall with 4 screws provided.
See figure 54.
5.
FS installations - Secure the appliance to the floor or wall if necessary.
9.5.
Installations except with Valor #551DVK Terminal – Installing to wall
Unless the wall is totally non-combustible, fit Dura-vent wall thimbles #942.
Slide the appliance into its correct position and install as detailed in the Duravent instructions supplied with the pipes.
FS installations - Secure the appliance to the floor or wall if necessary.
Figure 54
Figure 53
Figure 52