General

Approvals & codes

This appliance is certified by International Approval Services for use in Canada and the USA. The 

appliance is for installation connected to an approved 4” metal B type vent. 

This appliance is supplied for use with natural gas. It can be converted for use with LP gas with Kit 

#554LPK.

The appliance complies with CGA P.4.1, Testing method for measuring annual fireplace efficiencies.

The installation must conform with local codes or, in the absence of local codes with the National Fuel 

Gas Code, ANSI Z223.1or the Canadian installation code CAN/CGA-149. Only qualified licensed or 

trained personnel should install the appliance.

Ratings

¹When converted using kit #554LPK

²Tested to 

CAN/CGA - 2.17 Gas fired appliances for use at high altitudes

. In the USA installations 

may require deration over 2000ft - Check local codes.

Location

The President FS can be installed as a free standing unit with connected to a suitable type “B” vent or 

connected to an existing masonry chimney—see the section Dimensions & Clearances on page 3. 

The installation 

must

 conform to the minimum clearance dimensions shown in Dimensions & 

Clearance on page 3. 

An existing masonry chimney must be cleaned and checked to make sure that it is safe for use. 

Reline the chimney with an approved 4” flue liner installed according to the instructions supplied with 

the liner.

The appliance is suitable for fixing to the floor. If the appliance is installed directly on carpeting, tile 

or other combustible material other than wood flooring, it must be installed on a metal or wood panel 

extending the full width and depth of the appliance.

CAUTION! A GAS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A 

SEPARATE SOLID-FUEL BURNING APPLIANCE.

Natural Gas Propane Gas 

1

Altitude (ft)

0–4,500 

Input Maximum (Btu/h)

20,500

19,000

Input Mnimum (Btu/h)

6,500

12,500

Manifold Pressure (in w.c.)

3.5–3.9

10.3–10.7

Minimum Supply Pressure (in w.c.)

5.0

11.0

Содержание 530 B-Vent

Страница 1: ...ll the fire department This appliance is a domestic room heating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroo...

Страница 2: ...EVER OBSTRUCT the flow of combustion and ventilation air Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation Due to the high temperature the applian...

Страница 3: ...rculating Fan Kit 555CFK Having variable speed and temperature control it is designed to boost the natural convection process through the appliance It may be fitted before the fireplace is installed o...

Страница 4: ...can be installed as a free standing unit with connected to a suitable type B vent or connected to an existing masonry chimney see the section Dimensions Clearances on page 3 The installation must con...

Страница 5: ...he rear left corner of the appliance Pack Contents 552BVK B Vent Conversion Kit 1 B vent adapter unit with vent switch 1 Thermocouple interrupter 1 Case rear cover plate 2 P clips for wire fastening T...

Страница 6: ...unscrewing 12 screws Fit the rear cover plate supplied with the kit using the seal and 12 screws previously removed The hole in the cover plate must be nearest the top edge 1 Remove 4 screws from the...

Страница 7: ...f a turn Connect the vent switch wires into the thermocouple interrupter block Screw the thermocouple into the interrupter block until finger tight Make sure that the wires are properly located and fi...

Страница 8: ...ation Instructions supplied with the 530 engine Gas Supply Installation Refer to the Installation Instructions supplied with the 530 engine Aeration Setting Check Refer to the Installation Instruction...

Страница 9: ...r five minutes place smoke match or taper inside the opening in the B vent adapter box See figure below The installation is satisfactory if the smoke is drawn into the adapter box and up to the vent p...

Отзывы: