6. APPLIANCE PREPARATION
Detach the window
1.
Release the top of the window by pulling forward and
rotating outwards the two bars at the top corners. See
figure 2.
2.
Unscrew the two spring loaded bolts securing the bottom
of the window. See figure 2.
3.
Carefully lift the window. Keep the window and bolts in
a safe place.
Check ignition spark
The pilot burner and electrode unit is at the left end of the burner.
Push in the lighting knob and turn counter-clockwise through the
“IGN” position to “PILOT”. A spark should flash across from the
pilot electrode to the pilot burner shield. See figure 3.
Check flame control motor
1.
Fit the four batteries into the battery box (Which is
attached to the switch wires).
2.
Temporarily connect the switch wires to the control unit –
See figure 4.
3.
Operate the switch. This should cause the flame control
knob to rotate counter-clockwise. See figure 4.
4.
Disconnect and remove after checking.