10 of 18
7. VENTING & APPLIANCE FIXING
Preparing for Floor Fixing
If it is intended to fix the appliance to the floor, position the appliance in its final location checking that
the vent unit can be correctly installed. Mark through the two fixing holes in the appliance base. Move
the appliance away. Plug the holes if necessary.
Venting
Reposition the appliance in its final location Connect an approved 4” vent unit to the adapter collar.
Install the vent unit in accordance with the instructions supplied with the unit.
If installing to an existing masonry chimney, the chimney must be cleaned and checked to make sure
that it is safe for use. Reline the chimney with an approved 4” flue liner installed according to the
instructions supplied with the liner.
Floor fixing
If required, screw the appliance to the floor through the two holes in the base.