7.  VENTING & APPLIANCE FIXING  

Preparing for Floor Fixing  
If it is intended to fix the appliance to the floor, position the appliance in its final location checking that 
the vent unit can be correctly installed. Mark through the two fixing holes in the appliance base. Move 
the appliance away. Plug the holes if necessary.  
Venting 
Reposition  the  appliance  in  its  final  location  Connect  an  approved  4”  vent  unit  to  the  adapter  collar. 
Install the vent unit in accordance with the instructions supplied with the unit. 
If  installing  to  an  existing  masonry  chimney,  the  chimney  must  be  cleaned  and  checked  to  make  sure 
that  it  is  safe  for  use.  Reline  the  chimney  with  an  approved  4”  flue  liner  installed  according  to  the 
instructions supplied with the liner. 
Floor fixing 
If required, screw the appliance to the floor through the two holes in the base. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 530 B Vent

Страница 1: ...GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s ins...

Страница 2: ...flame control motor 7 B Vent Conversion Kit Installation 8 Attaching top air deflector 9 7 VENTING APPLIANCE FIXING 10 Preparing for Floor Fixing 10 Venting 10 8 FITTING SIDES SWITCH 11 9 GAS SUPPLY...

Страница 3: ...nd free from combustible materials gasoline and other flammable vapors and liquids Keep the vent unit and connector at the back of the heater at least 3inches from any combustible surfaces Keep the B...

Страница 4: ...ireplace is installed or retrofitted at a later date Kit 553RCK Circulating fan Having variable speed and temperature control it is designed to boost the natural convection process through the applian...

Страница 5: ...0 When converted using kit 554LPK Tested to CAN CGA 2 17 Gas fired appliances for use at high altitudes In the USA installations may require deration over 2000ft Check local codes 3 LOCATION The Presi...

Страница 6: ...lations 552BVK B Vent Conversion Kit 1 B vent adapter unit with vent switch 1 Thermocouple interrupter 1 Case rear cover plate 2 P clips for wire fastening 531CSB 532ESB 533ESG President Free Standing...

Страница 7: ...de unit is at the left end of the burner Push in the lighting knob and turn counter clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner...

Страница 8: ...ed The hole in the cover plate must be nearest the top edge See figure 6 3 Remove 4 screws from the case back 2 each side just outside of the cover plate Fit the adapter unit to the case using these s...

Страница 9: ...rmocouple into the interrupter block until finger tight Make sure that the wires are properly located and finally tighten the thermocouple nut with a wrench to secure the wires with good contact See f...

Страница 10: ...ry Venting Reposition the appliance in its final location Connect an approved 4 vent unit to the adapter collar Install the vent unit in accordance with the instructions supplied with the unit If inst...

Страница 11: ...in figure 15 Fit the batteries supplied with the engine unit to the holder supplied with the wall switch Fit the wall switch plate to your switch box c For active remote control Caution Don t connect...

Страница 12: ...ed in the line The tapping must be accessible for test gauge connection and be immediately upstream of the gas supply connection to the appliance 7 Pressure test the supply line for leaks The applianc...

Страница 13: ...g will give optimum performance and should not be altered In a few unusual installations performance may be improved by adjusting the aeration The need for adjustment should be determined by operating...

Страница 14: ...he rear wall by loosening the channel securing screws and adjusting the position of the channels See figure 22 3 Remove two screws from under the top front of the firebox Using these screws fit the po...

Страница 15: ...his log on the projection at front center of the base log It is important that the narrow nose does not drop down to touch the burner See figure 27 8 Place the left side log on base log at the left si...

Страница 16: ...appliance rocker switch wall switch remote hand unit See owner s lighting instructions further on in this manual for full details Aeration adjustment As described in section 11 burner aeration is adj...

Страница 17: ...ing in the B vent adapter box See figure 32 The installation is satisfactory if the majority of the smoke is drawn into the adapter box and up to the vent pipe If the vent is blocked or has strong rev...

Страница 18: ...shown in figure 33 2 Fit the top casting making sure that the corners locate as shown in figure 34 3 Fit the top infill casting See figure 35 4 If necessary the appliance can be leveled by the adjustm...

Отзывы: