NOTE: Cleaning ceramic fuel effect pieces.
This product uses fuel effect pieces and gaskets containing Refractory Ceramic
Fibres (RCF), which are man-made vitreous silicate fibres. Excessive exposure
to these materials may cause irritation to eyes, skin and respiratory tract.
Consequently, it is important to take care when handling these articles to
ensure that the release of dust is kept to a minimum. To ensure that the release
of fibres from these RCF articles is kept to a minimum, during installation and
servicing we recommend that you use a HEPA filtered vacuum to remove any
dust and soot accumulated in and around the fire before and after working on
the fire. When replacing these articles we recommend that the replaced items
are not broken up, but are sealed within a heavy duty polythene bag, clearly
labelled as RCF waste. RCF waste is classed as a stable, non-reactive
hazardous waste and may be disposed at a landfill licenced to accept such
waste. Protective clothing is not required when handling these articles, but we
recommend the use of suitable gloves to prevent irritation. We also recommend
you follow the normal hygiene rules of not smoking, eating or drinking in the
work area and always wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos
or asbestos related products.
MAINTENANCE
Regular maintenance.
In order to achieve and maintain high levels of personal safety and performance
efficiency it is essential that the flue terminal outside the building is kept clear of any
form of obstruction.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant’s premises checked for safety at least
every twelve months by a competent person (In the UK a GAS SAFE REGISTER
engineer, Outside of the UK a CORGI or GAS SAFE REGISTER engineer).
We recommend that all gas appliances and their flues, wherever situated, are
checked annually.
-
When fitting replacement parts it is important that only approved parts are
used for maximum safety.
Page 31
©
GDC Group Ltd. 2014
OWNER GUIDE
Содержание 474 Valentia
Страница 4: ...Page 4 GDC Group Ltd 2014 INSTALLER GUIDE INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 24 TO 35...
Страница 13: ...Page 13 GDC Group Ltd 2014 INSTALLER GUIDE Fig 4...
Страница 23: ...Page 23 GDC Group Ltd 2014 INSTALLER GUIDE...
Страница 24: ...Page 24 GDC Group Ltd 2014 OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 32 TO 35 OWNER GUIDE...
Страница 36: ...Page 36 GDC Group Ltd 2014...
Страница 37: ...Page 37 GDC Group Ltd 2014...