Valor 474 Valentia Скачать руководство пользователя страница 15

6. PREPARATION OF WALL

NOTE:

The following instructions relate to normal brick walls. If the wall is wholly or

partly of combustible material, a combustible wall kit (optional extra) must be used. 

Check the wall thickness. Three different sizes of flue available for wall thickness up

to 508mm as shown below. The medium flue is packed with the heater, the other

lengths must be ordered specially.

Min (Telescopic) -

150mm

to

203mm

Short

-

75mm

to

203mm

Medium 

-

200mm

to

356mm

Long

-

356mm

to

510mm

Place the template against the wall ensuring the top is level. For hearth mounting,

ensure that the centre of the flue is 351mm above the hearth. Mark the positions of

the flue and four fixing holes and remove the template.

Cut the hole for the flue making sure that it is straight and level. This can be done

with either a 135mm diameter core drill or hammer and chisel. If neatly drilled no

making good is necessary. If not it will be necessary to make good the hole especially

at the terminal end where the flue seal will be located and the inside wall face to

achieve a good seal.

Use the template to mark the fixing holes if necessary. Drill the four fixing holes to a

minimum depth of 57mm using 6mm diameter masonry drill and insert the plugs.

Page 15

© 

GDC Group Ltd. 2014

INSTALLER GUIDE

FIG. 6

Содержание 474 Valentia

Страница 1: ...this guide gives sufficient details to enable this appliance to be installed operated and maintained satisfactorily However if further information is required our Valor Technical Helpline will be ple...

Страница 2: ...to the following address The Marketing Communications Manager GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton SO30 2DF Warning Any person who does any unauthorised act in relation to...

Страница 3: ...e British Standards Institute The Highest Standards Valor Fires is a member of SBGI and HHIC Heating and Hot water Industry Council that work to ensure high standards of safety quality and performance...

Страница 4: ...Page 4 GDC Group Ltd 2014 INSTALLER GUIDE INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 24 TO 35...

Страница 5: ...PACK CONTENTS 14 6 PREPARATION OF WALL 15 6 1 Combustible Walls 16 6 2 Installations in Timber Frame Buildings 16 7 PREPARATION OF FIRE 17 7 1 Remove Outer Case 17 7 2 Fit Flue 17 7 3 Connect Gas Supp...

Страница 6: ...er Case 20 9 2 Gas Tap Assembly 20 9 3 Burner Assembly 20 9 4 Main Burner Injectors 21 9 5 Pilot Injector SIT No 34 21 9 6 Pilot Filter 21 9 7 Thermocouple 21 9 8 Spark Electrode 21 9 9 Pilot Burner 2...

Страница 7: ...Refractory Ceramic Fibres RCF which are man made vitreous silicate fibres Excessive exposure to these materials may cause irritation to eyes skin and respiratory tract Consequently it is important to...

Страница 8: ...993241 Medium flue for walls from 200mm to 356mm No 993240 Long flue for walls from 356mm to 510mm No 993239 NOTE The fire is supplied with Medium flue only Short Long flues are optional extras 3 APP...

Страница 9: ...with the current edition of the Gas Safety Installation and Use Regulations Failure to install the appliance correctly could lead to prosecution GAS SAFE REGISTER and CORGI require their members to w...

Страница 10: ...mbustible wall such that the bottom of the backplate of the fire is at least 60mm above the finished floor level NOTE Soft wall coverings e g blown vinyl wallpaper may become discoloured if close to a...

Страница 11: ...is measured from the extreme side of the fascia This will allow easy access This clearance is mandatory for temperature requirements 4 3 2 2 For any combustible projections beyond 178mm Measured from...

Страница 12: ...round roof or balcony level 300mm J From a surface facing the terminal 600mm K From a terminal facing the terminal 600mm L From an opening in a car port e g door window into dwelling 1200mm M Vertical...

Страница 13: ...Page 13 GDC Group Ltd 2014 INSTALLER GUIDE Fig 4...

Страница 14: ...ing screws 2in wood 810500 4 x Wall plugs 820813 3 x M4 x 10 Taptite screws air duct 810327 2 x No 6 S T x 10 posi pan 810776 5 Foam seal pack 822092 6 A template representing the backplate full size...

Страница 15: ...level For hearth mounting ensure that the centre of the flue is 351mm above the hearth Mark the positions of the flue and four fixing holes and remove the template Cut the hole for the flue making su...

Страница 16: ...e outer leave of the wall is constructed of non combustible material then cut the hole 135 mm diameter making allowances for the shrinkage of the timber frame d Measure the thickness of the combustibl...

Страница 17: ...case away from the fire and put in a safe place e Remove the glass door by removing the wingnuts on the door surround Lift off the glass door and put in a safe place 7 2 Fit Flue a Place the heater f...

Страница 18: ...ed by hand until it is flush with the surface of the flue f Insert the two top wall fixing screws leaving the plain shank projecting to allow the keyhole top fixing holes to go over them Offer the fir...

Страница 19: ...case by placing it over the fire right hand side first and ensure that the spindle enters the hole in the knob housing before swinging the left side of the case onto the fire Fit four screws two each...

Страница 20: ...g the gas tap to the support bracket on the fire Manoeuver the gas tap complete with inlet pipe away from the fire after disconnecting the inlet pipe clamp b Replacement Ensure that the new gas tap is...

Страница 21: ...and feeds gas to the outer burner sections 9 5 PILOT INJECTOR SIT No 34 a Release the tubing nuts at each end of the gas supply tube and remove the tube taking care not to lose the pellet filter in t...

Страница 22: ...INSTALLER GUIDE PART NUMBER DESCRIPTION 991979 Coal Bed 991725 Control Knob 987623 Gas Tap c w switch 820363 Spark Electrode 822131 Pilot Filter 822205 Thermocouple 991635 Door Assembly 987632 Igniti...

Страница 23: ...Page 23 GDC Group Ltd 2014 INSTALLER GUIDE...

Страница 24: ...Page 24 GDC Group Ltd 2014 OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 32 TO 35 OWNER GUIDE...

Страница 25: ...tia is a room sealed live fuel effect gas fire with coals It has a balanced flue system which takes air for combustion from the outside and discharges products of combustion to the outside It must be...

Страница 26: ...automatically shut off the gas supply to the fire if for any reason the flames go out Do provide a minimum clearance of 150mm from the extreme top surface of the fire to any shelf made of wood or othe...

Страница 27: ...is a heating appliance and certain parts of its surface will become hot Do get advice about the suitability of any wall covering near your fire Soft wall coverings e g embossed vinyl etc which have a...

Страница 28: ...1A The ignition spark generator battery powered size AA is located at the lower rear RH side WARNING If the pilot light is extinguished either intentionally or unintentionally no attempt should be mad...

Страница 29: ...tings 1 HIGH 2 and ECON See Fig 1A Setting 1 provides gas to the full burner at a low level Setting HIGH gives the full heat output Setting 2 uses about the same amount of gas as 1 but limits this to...

Страница 30: ...door as previously instructed then lift the coal bed straight out Take care as the coal bed is a fragile component When replacing ensure that the end cut out of the coal bed is positioned over the pil...

Страница 31: ...Protective clothing is not required when handling these articles but we recommend the use of suitable gloves to prevent irritation We also recommend you follow the normal hygiene rules of not smoking...

Страница 32: ...s an annual service every 12 months in accordance with the installation and servicing instructions performed by a GAS SAFE REGISTER operative Our promise to you If you experience a fault with your new...

Страница 33: ...if you do not have the fire serial number Note Details 1 4 should be recorded on pages 34 35 at the end of this guide What this warranty covers Free of charge repair or replacement of components found...

Страница 34: ...4 Page 34 To be completed by installer OWNER GUIDE Installer Details Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number...

Страница 35: ...Capitals Fascia code Can be found close to the information label Block Capitals Model 4 7 3 Serial number Can be found on the bottom RHS of the Fascia OWNER GUIDE A LABEL CONTAINING THE SERIAL NUMBER...

Страница 36: ...Page 36 GDC Group Ltd 2014...

Страница 37: ...Page 37 GDC Group Ltd 2014...

Отзывы: