62
Screw
Wing nut below
Wing nut below
Air shutter
Close
Open
Install Trim and Barrier Screen
Install the trim chosen by the customer for their
fi
replace. Install as well the barrier screen which is
provided with the trim.
Show the customer how to remove the barrier screen
to access the controls.
Follow the instructions provided with the trim and leave
those instructions behind for the customer’s further
reference.
Check Operation
Turn the
fi
replace
fl
ame up and down using the
remote control to con
fi
rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 11–15.
Adjust Aeration if needed
Light the
fi
re and allow the unit to warm up for 10–15
minutes to evaluate the
fl
ame picture. The burner is
equipped with an adjustable shutter to control primary
aeration. The shutter is factory-set to an aeration gap
which will give optimum performance for the vast
majority of installations.
In a few unusual installations, the
fl
ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the fuel bed and window installed.
Increasing aeration
will cause the
fl
ames to appear
more transparent and blue showing more ceramic
effects glow.
Decreasing aeration
will cause the
fl
ames to appear
more yellow or orange showing less ceramic effects glow.
Too little aeration may result in black carbon forming
on logs or roof panel and dropping into the
fi
rebox.
Air Shutter
To access the air shutter, very carefully remove the
ceramic fuel bed. The air shutter is located under the
ceramic fuel bed at the back as shown.
Loosen the air shutter screws, adjust and re-tighten.
Installation
QUALIFIED