20
X
Ratings
Model
1100IN
1100IP
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
28,000
28,000
Input Minimum (Btu/h)
13,000
13,000
Manifold Pressure (in w.c.)
3.5”
9”
Minimum Supply Pressure (in w.c.)
5”
11”
Maximum Supply Pressure (in w.c.)
10”
14”
Main Burner Injector Marking
850
300
Pilot Injector Marking
51
30
Min. Rate By-Pass Screw
185
125
Model
1150ILN 1150ILP
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
30,000
30,000
Input Minimum (Btu/h)
13,500
13,500
Manifold Pressure (in w.c.)
4”
9”
Minimum Supply Pressure (in w.c.)
5”
11”
Maximum Supply Pressure (in w.c.)
10”
14”
Main Burner Injector Marking
850
360
Pilot Injector Marking
51
30
Min. Rate By-Pass Screw
185
125
Speci
fi
cations
Approval & Codes
This appliance is certi
fi
ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for
Vented Gas Fireplace Heaters
for use in
Canada and USA, and to CGA 2.17-91
High Altitude
Standard in Canada
. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09
Testing
method for measuring annual
fi
replace ef
fi
ciencies
.
The installation must conform to local codes or, in the
absence of local codes, with the
National Fuel Gas
Code, ANSI Z223.1
or the
Natural Gas and Propane
Installation Code CAN/CGA-B149
. Only quali
fi
ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA
70
or the
Canadian Electrical Code, CSA C22.1
.
*High Altitude Installations
I
nput ratings are shown in BTU
per hour and are certi
fi
ed without
deration for elevations up to
4,500 feet (1,370 m) above sea
level.
For elevations above 4,500 feet
(1,370 m) in USA, installations
must be in accordance with the current ANSI Z223.1
and/or local codes having jurisdiction. Heating value
of gas in some areas is reduced to compensate for
elevation—consult your local gas utility to con
fi
rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engines 1100IN and 1150ILN are used with
natural gas.
Heater engines 1100IP and 1150ILP are used with
propane gas.
The supply pressure must be between the limits shown
in the
Ratings
section.
The supply connection is 3/8” NPT male and located on
the right hand side of the
fi
rebox. A shut-off valve (not
supplied) is required on the supply line to isolate the
unit during service. See
Supply Gas Installation
section
for details.
Conversion Kits
The 1100 and 1150 are supplied as natural gas or
propane gas and are
fi
eld convertible between fuels.
See instructions packaged with the conversion kits for
further information.
Electrical
The 1100 and 1150 are designed to run on battery
power and do not require an electrical power source to
operate as a heater. However, they require electrical
power to operate optional 1195CFK Circulating Fan
Kit, 1270RBK Remote Blower Kit or GV60PAK Power
Adapter.
QUALIFIED