45
combustible floor
base of heater
non-combustible material
gap for air flow
(must be free at all time)
trim’s removable panel
max. 1” total thickness of hearth
1/2”
Micore
board
(provided)
Non-combustible hearth with 1130 Minimal Trim—cross-section
Gap
for air-
ow
1130MTB Minimal Trim Kit
Install Appliance with 1130 Minimal Trim Kit
Part of the 1130 Minimal Trim Kit installs at the time of
framing the appliance.
The side brackets provided loose with the appliance
are not needed with this kit.
The 1130 Minimal Trim is not compatible with any
other trim or door kits.
Hearth considerations
You need to know whether there will be a hearth or
not in front of the appliance and some rules must be
considered:
Without hearth
In the case where there is no hearth, the bottom
of the appliance must be raised at least 4” inches
above any combustible
fl
oor in front.
With hearth
•
Only a non-combustible hearth can be installed
in front of the appliance if within 4” vertically
of the bottom of the appliance. See
Hearth
Requirements
section of this manual.
•
The non-combustible hearth in front of the
appliance, if within 4” of the bottom of the
appliance, must include the 1/2”
Micore
insulation
board provided to be used as thermal break
between non-combustible and combustible
material underneath.
•
A non-combustible hearth of up to 1” total
thickness may be butted up to the heater
otherwise the heater must be raised to
accomodate the hearth thickness. See details on
the right.
Kit content
LH
side
panel
RH side
panel
Upper
panel
LH side
door
RH side
door
Removable
panel
Barrier
screen
Installation
QUALIFIED
INSTALLER