Q
What opening size do you need in the surround or fireplace opening?
A
This heater can be fitted into fireplaces or surrounds where the following
dimensions are available.
Width
395mm - 450 mm
Height
555mm - 590 mm
Depth
At least 145mm
Q
Do you want to fit the heater into a surround using the spacer frame
supplied with the heater?
A
The minimum rebate required is 65mm.
Q
Do you want to fit the heater against a flat wall with the base of the heater
on a hearth or similar surface?
A
You will need to purchase the optional spacer frame kit (kit number 0582631).
This spacer when added to the one supplied with the heater enables the heater
to be flat wall fixed. The depth of the combined spacer frames is 160mm.
General notes to read before fitting your heater.
There should be at least 50mm clearance between the top of the fascia and anything
such as a shelf, fireplace surround or mantel etc. This will allow the fascia to be lifted
off or removed during servicing. To check the shelf clearance gently place the fascia
against the surface to which it is to be fixed and measure the distance from the top of
the fascia.
If fitting the heater onto a reflective or shiny surface such as a hearth we recommend
that this surface does not extend further than 300mm from the fixing plane (wall).
Reflective or shiny surfaces that project further than 300mm may reflect an image of
the internal light source.
Fitting the cable clamp.
If the mains cable is to be routed to the left hand
side of the heater there is a cable clamp supplied
with the heater to hold the cable in place. This
prevents the cable being trapped under the heater
during installation. Fit the cable clamp as in figure
1.
Figure 1. Fitting the cable clamp
©
Baxi Heating U.K. Limited 2008.
INSTALLER AND OWNER GUIDE