17.10 To remove the electronic ignition generator.
1.
Remove the bottom front cover, fire front
castings, the fascia, glass panel and fuel effect as
in section 17.7.
2.
Remove the battery.
3.
Remove the spark lead.
4.
Unscrew the four support bracket screws (See
figure 42). The generator and its support bracket
can now be moved forward. Be careful not to apply
tension to the microswitch leads.
5.
Remove the two fixing screws that attach the
generator unit to the support bracket. The igniter
generator can now be removed (See figure 42)
6.
Remove the two leads to the switch and remove
the spark lead. If necessary, mark them to ensure
that they are replaced on to the correct terminals.
7.
Replace the generator
8.
Refit in the reverse order.
17.11 To remove the complete burner unit.
1.
Remove the bottom front cover, fire front
castings, the fascia, glass panel and fuel effect as
in section 17.7
2.
Close the isolating valve in
the inlet ‘T’ connector. Support
the inlet ‘T’ connector to avoid
straining the pipework and
disconnect the appliance from
the ‘T’ connector.
3.
Detach the burner unit from
the convection box by removing
two screws (See figure 43).
4.
Replace in the reverse order.
©
Baxi Heating U.K. Limited 2008.
Page 39
Figure 43. Burner attachment points
Figure 42. Removal of
electronic generator
INSTALLER GUIDE