accordance with BS 5440: Part 1 Annex A, the minimum
equivalent
height of the flue
shall be 2.0m of 125mm dia. flue pipe.
4.5
The flue must not be used for any other appliance or application.
4.6
Any chimney damper or restrictor should be removed. If removal is not possible,
they must be secured in the open position.
4.7
If the appliance is intended to be installed to a chimney that was previously used
for solid fuel, the flue must be swept clean prior to installation. All flues should be
inspected for soundness and freedom from blockages.
4.8
If the fireplace opening is an underfloor draught type, it must be sealed to stop
any draughts.
4.9
The appliance must be mounted behind a non-combustible hearth unless the
conditions of section 4.2.1.1 are met (N.B. conglomerate marble hearths are
considered as non-combustible). The appliance can be fitted to a purpose made
proprietary class “O”-150°C surround. The hearth material must be at least 12mm
thick. The periphery of the hearth (or fender) should be at least 50mm above floor
level to discourage the placing of carpets or rugs over it.
The surface of the hearth must be sufficiently flat to enable the bottom of the front
surround and the bottom front cover to be aligned horizontally. Any excessive
unevenness (uneven tiles, Cotswold stone, etc.) should be rectified.
The appliance must not stand on combustible materials or carpets
.
4.10
The front face of the fireplace should be reasonably flat over the area covered
by the convection box top and side flange seals to ensure good sealing. These faces
should be made good if necessary. The fireplace floor should be reasonably flat to
ensure that a good seal with the convection box can be made.
4.11
Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by
heat. They may scorch or become discoloured when close to a heating appliance.
Please bear this in mind when installing.
4.12
This appliance must not be installed in any room that contains a bath or shower
or where steam is regularly present.
4.13
An extractor fan may only be used in the same room as this appliance, or in any
area from which ventilation for the appliance is taken, if it does not affect the safe
performance of the appliance. Note the spillage test requirements detailed further on
in this manual. If the fan is likely to affect the appliance, the appliance must not be
installed unless the fan is permanently disconnected.
©
Baxi Heating U.K. Limited 2008.
Page 12
INSTALLER GUIDE