16.1 Checking the aeration setting of the burner.
1.
The aeration shutter is factory set for
use with a ‘
pebble
’ ceramic fuel effect. It
is important to ensure that the aeration
setting is correct for the ceramic fuel
effect used. Check the aeration shutter
setting even if fitting the ‘pebble’ fuel
effect (See figure 24).
2.
To adjust the aeration setting to suit
the fuel effect used, loosen the two
shutter screws, slide the aeration shutter
to the desired position and tighten the
fixing screws.
16.2 To remove the complete burner
unit.
1.
Remove the lower fascia trim. This is held in place
with strong magnets. Hold the outer edges and pull
away from the fascia.
2.
Remove the two fascia securing screws (See
figure 25).
3.
Remove the fascia. To do this, hold the fascia
sides, gently pull the base of the fascia forward and
lift clear of the upper retaining brackets.
4.
Remove the ceramic fuel effect.
5.
Support the inlet ‘T’ connector to avoid straining
the pipework and disconnect the
appliance from the inlet ‘T’
connector.
6.
The remote control receiver box
at the right hand side of the hotbox
base is held in place with hook
and loop material tape. Hold the
top of the receiver box and pull
forward to remove.
7.
Detach the burner unit from the
hotbox by removing two screws
(See figure 26).
8.
Replace in the reverse order.
Pa ge 3 0
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 24. Aeration plate settings for ‘coal’
and ‘pebble’ ceramic fuel effects.
Figure 26. Burner attachment points
Figure 25. Fascia securing