8. PREPARING APPLIANCE FOR INSTALLATION
1.
Detach the burner unit from the
hotbox by removing two screws (See
figure 10). Lift the burner unit clear.
2.
Fit the two “U” section seals to the
bottom edges of the hotbox side
flanges (See figure 11).
3.
It is important that the grommet
supplied in the loose parts pack is
fitted to the hole in the rear of the
hotbox.
For concealed connection only:
Pierce the grommet to allow the pipe to pass through it.
The grommet should envelop the pipe. If the hole is
larger than the pipe, seal it with tape.
Do not pierce the
grommet unless the supply pipe is to pass through
it
.
4.
The appliance is supplied with two fireback spacers.
Do not fit the fireback spacers if the fire is to be
installed into a precast or clay flue block system as in
section 3.10.3
. These should extend backwards to
ensure sufficient clearance from the back of the fireplace.
Remove the label and retaining screws from the rear
sides of the hotbox. Position the fireback spacer as
shown in figure 12. Secure the fireback spacers using
the screws removed previously and the two supplied
with the fire.
Page 22
©
Baxi Heating U.K. Limited 2009.
Figure 12. Fireback spacers
Figure 11. ‘U’ Seals
INSTALLER GUIDE
Figure 10. Burner attachment points