121: Error
board and the HVPS unit
properly connected?
Is the contact point
defective?
Yes
No
Check the connection with the
HVPS.
Replace the HVPS.
SERVICE CALL
122: Error
LVPS Fan Error
Is the LVPS fan (front right
side at the bottom)
operating?
Is the fan connector correctly
connected?
No
Yes
No
Yes
Check the connection of the fan
connector.
Replace the PU board.
Replace the fan motor.
Replace the PU board.
SERVICE CALL
123: Error
Ambient Humidity
Abnormality/No
Humidity Sensor
Connected
Does the error occur again?
Yes
Turn the power OFF/ON.
Replace the control panel.
SERVICE CALL
124: Error
Ambient Temperature
Abnormality
Does the error occur again?
Yes
Turn the power OFF/ON.
Replace the control panel.
SERVICE CALL
125: Error
MPT Home Location
Error Detection
Is the error message
displayed after reapplying the
power?
Yes
Replace the MPT.
SERVICE CALL
126: Error
Dew condensation
(moisture) on the
equipment detected
It can easily happen when
the equipment is brought in
from outdoor area. Does the
error occur again when the
power is turned on after
leaving the unit in room
temperature for 2 hours to a
quarter of a day?
Yes
Reapply the power after leaving the
unit alone.
Replace the control panel.
SERVICE CALL
127: Error
Fuser Exhaust Fan Error
Is the connection of the Fan
Connector normal?
Does the error occur again?
No
Yes
No
Normally connect it again. Replace
the fan motor.
Replace the PU board.
SERVICE CALL
127: Error
Engine Fan Error
01: Fuser Fan Error
02: Power Fan Error
03: PU, Motor Fan Error
04: Belt Fan Error
05: ID Fan Error
06: Top Cover Fan Error
Connect the relevant Fan
Connector again.
If the situation does not change,
replace the Fan.
SERVICE CALL
128: Error
Fuser Cooling Fan Error
Is the connection of the Fan
Connector normal?
Does the error occur again?
No
Yes
No
Normally connect it again. Replace
the fan motor.
Replace the PU board.
SERVICE CALL
131: Error ~
134: Error
Occurrence of LED
Head Error
(131=Y, 132=M
133=C, 134=K)
Is the LED head correctly
installed?
Is the LED HEAD FUSE
disconnected?
Does the error occur again?
No
Yes
No
Yes
Reinstall the LED HEAD Unit.
Check the LED HEAD FUSE.
Check/replace the FUSE.
Turn on the power again.
Replace the LED HEAD Unit.
SERVICE CALL
140: Error ~
142: Error
Up/Down Location
Detection Error of ID
(140=Y, 141=M, 142=C)
Is there anything which
stands in the way when
installing the Drum?
Does the error occur again?
Yes
No
Yes
Reinstall the Drum.
Turn on the power again.
Check the operation of the ID
Up/Down Motor.
SERVICE CALL
Toner Supply Switch
Is the Drum correctly
No
Reinstall the Drum.