background image

14

TECHNICAL SPECIFICATIONS

Sound power level in the supply air duct (one duct)  

by octave band L

w

, dB

Adjustment position

Sound power level in the extract air duct (one duct)  

by octave band L

w

, dB

Adjustment position

Adjustment position (%)

10

20

30

40

50

60

70

80

100

10

20

30

40

50

60

70

80

100

Air flow dm³/s

6

10

17

21

26

32

35

40

44

7

14

22

24

30

35

40

45

48

Medium 

frequency 

of the octave 

band Hz

63

59

66

70

72

74

79

78

79

81

55

59

61

64

67

76

72

72

73

125

57

62

64

66

69

71

73

76

76

57

60

62

66

68

70

72

74

77

250

47

55

62

66

68

69

71

73

73

39

47

55

60

61

62

63

65

67

500

36

44

50

55

59

63

66

68

70

26

33

38

42

47

52

55

57

57

1000

29

39

45

50

54

59

61

63

65

21

29

34

38

42

45

48

50

52

2000

21

29

39

45

50

53

56

58

60

13

15

22

27

32

35

37

39

41

4000

18

19

24

32

40

46

50

53

55

17

17

18

18

21

25

28

32

34

8000

21

21

22

23

26

31

36

40

43

21

22

21

21

22

22

22

22

23

L

W

,dB 

62

67

71

74

76

80

80

81

83

59

62

65

69

71

77

75

77

79

L

WA

, dB(A)

44

51

56

60

63

66

68

72

72

41

45

50

54

56

58

60

62

64

Sound pressure level coming through the envelope of the unit in the room in which it is installed (10m² sound absorption)

Adjustment position / Air flows (supply/extract)

Adjustment position (%)

10

20

30

40

50

60

70

80

100

Air flow dm³/s

6/7

12/14

19/22

22/25

27/30

 31/34

35/40

41/45

44/48

L

pA

, dB (A)

24

29

35

38

40

45

47

49

50

SOUND VALUES

TECHNICAL SPECIFICATIONS

Product title

Vallox TSK Multi 80 MV R

Vallox TSK Multi 80 MV L

Product number

3530300

3530400

Air volumes

 

Supply air

 

Extract air

85 dm

3

/s, 100 Pa

96 dm

3

/s, 100 Pa

Fans

 

Supply air

 

Extract air

0,071 kW 0,5 A EC

0,071 kW 0,5 A EC

Post-heating

Electrical resistor, 900 W

Electrical connection

230 V, 50 Hz,  8,8 A power plug

Pre-heating

Enclosure protection class

IP 34

Additional heating

Electrical resistor, 900 W

Heat recovery bypass

Automatic

Filters

 

Supply air

 

Extract air

ISO Coarse > 75 % + ISO ePM₁

ISO Coarse > 75 % 

  

Specific energy consumption (SEC)

 

in a cold climate 

 

in a temperate climate

A+

B

Operating efficiencies

 

 

Annual efficiency

 

Supply air efficiency

 

Specific Fan Power (SFP)

75 % A+

85 %

0.9 kW (38 dm

3

/s) A

Dimensions

 (w x h x d) 

1026 x 293 x 626 mm

Weight

58,5 kg

Содержание TSK Multi Series

Страница 1: ...50 MV Vallox TSK Multi 50 MV EH Vallox TSK Multi 80 MV Vallox TSK Multi 80 MV EH Vallox TSK Multi 80 MV EHX Type A3609 1 A3609 B3608 1 B3608 B3608 2 Document D5321 Valid from 14 04 2020 Updated 18 03...

Страница 2: ...Before beginning maintenance work 9 Changing the filters 9 Cleaning the heat recovery cell 10 Condensing water 10 Cleaning the fans 11 Cleaning the supply air fan 11 Cleaning the extract air fan 12 T...

Страница 3: ...odifications or changes made to the software INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to...

Страница 4: ...result in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoided CAUTION Indicates a hazard that can result in minor o...

Страница 5: ...ws for controlling ventilation remotely also using e g a smartphone or tablet Also the unit software is updated automatically through the cloud service To connect to the cloud service the ventilation...

Страница 6: ...act air 7 Bypass damper of the HR cell 8 R model in the figure MAIN PARTS Vallox TSK Multi 50 MV and Vallox TSK Multi 80 MV Safety switch 9 Control panel 10 Internal humidity sensor 11 Internal carbon...

Страница 7: ...ront of the unit for servicing purposes The service space in front of Vallox TSK Multi 50 MV must be at least 530 mm The service space in front of Vallox TSK Multi 80 MV must be at least 600 mm NOTE T...

Страница 8: ...female 125 female E 87 110 F 197 254 G 86 110 H 161 200 I 161 200 J 86 96 K 96 96 L 206 231 M 498 624 N View from right O View from above P View from left Q Right side R Left side S Seen from behind L...

Страница 9: ...and dust particles out of the supply air Coarse filter for extract air filters the extract air and keeps the heat recovery cell clean To replace the filters 1 Disconnect the ventilation unit from the...

Страница 10: ...water to which a small amount of a mild detergent has been added 10 Rinse the cell clean with a water spray Do not use a high pressure cleaner 11 When all the water has drained from between the layer...

Страница 11: ...2 Unfasten the four screws to open the door of the unit 3 Lift the door off CAUTION The door is heavy 4 Remove the extract air filter C the cell top bracket E and the heat recovery cell D as described...

Страница 12: ...oving the supply air fan Figure 1 6 Remove the connector package from the wall 7 Separate the connectors from each other 8 Tilt the fan to the left and turn 90 9 Tilt the fan forward to pull it out of...

Страница 13: ...ressure loss in the extract and supply air ducts extract air supply air TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS AIR FLOWS AND SOUND VALUES Pressure loss in ducts Total pressure Pa Volume flo...

Страница 14: ...3 66 68 72 72 41 45 50 54 56 58 60 62 64 Sound pressure level coming through the envelope of the unit in the room in which it is installed 10m sound absorption Adjustment position Air flows supply ext...

Страница 15: ...vel in the supply air duct one duct by octave band Lw dB Adjustment position Sound power level in the extract air duct one duct by octave band Lw dB Adjustment position Adjustment position 10 20 30 40...

Страница 16: ...TSK Multi 50 MV EH Vallox TSK Multi 80 MV EH EHX R2 Additional heating resistor with 90 C and 130 C overheating protection Vallox TSK Multi 80 MV EHX BK Black BU Blue BN Brown WT White GY Grey YE Yell...

Страница 17: ...D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input RM O 24V relay output EXTERNAL ELECTRICAL CONNECTION Analog input two different functions Potential fr...

Страница 18: ...the supply air temperature will be maintained at the level specified in the temperature setting In winter the duct radiator will turn on when the outdoor temperature falls below the winter setting Ma...

Страница 19: ...ve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example ELV05006 Stig Wahlstr m K Condensing water tube Not included in the deliv...

Страница 20: ...External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Local hardware Modbus B signal NTC External t...

Страница 21: ...tional heating resistor L model Vallox TSK Multi 80 MV 942211 15 Side sealing strip of the heat recovery cell Vallox TSK Multi 50 MV 3356300 15 Side sealing strip of the heat recovery cell Vallox TSK...

Страница 22: ...CONFORMITY CERTIFICATES...

Страница 23: ......

Страница 24: ...www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Customer service 358 10 7732 200 Aftersales 358 10 7732 270 D5321 18 03 2020FIN 18 03 2020ENG PDF...

Отзывы: