Installation Instructions
Specifi cations are subject to change without notice
Page 1
[email protected] | www.manrose.co.nz
Distributed by Simx Limited
QUIET 150mm Extraction Fan Kit
Mounting
Switching
Product Code
Through Wall
Standard
FAN7190
Timer
FAN7191
Humidity Control
FAN7192
For best results, Simx recommend this product for bathrooms and kitchens.
In kitchen installations, do not install the fan kit, laterally, any closer than 2m
from the cooktop.
In bathroom installations the fan kit can be installed within 1.5m, laterally, of the
steam source and immediately above the bath or shower tray up to the higher of
either 2.25m or the height of the fi xed plumbing connection.
Once installed, following these instructions, this product will meet the Healthy
Homes Standard for through wall, or ceiling, mount installations in rental property
bathrooms or kitchens.
This product will also comply with the G4 Building Code for through wall mount
installations in bathrooms and kitchens.
DIMENSIONS
SPECIFICATIONS
Duct
(mm)
Max.
Fan Watts
(W)
Max.
Fan Pressure
(Pa)
Free Air Fan Performance
Specific
Fan Power
(W/l/s)
Sound
dB(A)
Operating
Temperature
(max.)
IP Rating
(l/s)
(m
3
/hr)
150
22
138
114
410
0.19
41
40°C
IPX4
Compliance: AS/NZS60335-2.80:2016
A
D
F
C
E
H
B
G
C
H
CONTENTS
150mm x 375mm
Weatherproof
Axial Fan
Aluminium Semi-Rigid Duct
Cowl
CAUTION
• Before use, please check that the supply voltage and that of the appliance are the same (see product rating label).
• All wiring and wiring connections must comply with all current national wiring rules and regulations including AS/NZS3000:2018, or latest
edition
thereof.
• Any changes or modifi cations made or attempted to this product, without the prior written approval of the manufacturer, will void any and all
stated
warranties.
• This fan is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are capable of, and have been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
• Precautions must be taken to avoid the back fl ow of combustion gases from the open fl ue of gas or other fuel-burning appliances in the room,
or from other rooms. These gases can potentially result in carbon monoxide poisoning. Open fl ued gas appliances should be tested by a
competent person, after fan installation, to ensure that back fl ow of combustion gases does not occur.
WARNING
• Do not insert or allow foreign objects to enter any ventilation openings, as this may cause an electric shock, fi re or damage to the fan.
• Do not put fi ngers or foreign objects into the grille while in operation.
• To prevent overheating of this fan, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and
outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER.
• Do not use it in areas where gasoline, paint, or fl ammable liquids are used or stored.
• This product contains recyclable materials. Do not dispose of this product as unsorted council waste. Please contact your local council for the
nearest collection point.
WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED TO REDUCE THE RISK OF PROPERTY DAMAGE OR PERSONAL INJURY.
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN
ACCORDANCE WITH THE LATEST WIRING RULES AS/NZS3000.
Cut-Out Size
A
B
C
D
E
F
G
H
173
174
30
150
375
146
111
30.5
227