background image

Pressure loss in ducts. T

otal pressure.

Volume flow rate

E = Extract air fan

S = Supply air fan

E = Extract air fan

S = Supply air fan

Pressure loss in ducts. T

otal pressure.

Volume flow rate

ED and SD are examples of pressure

losses in supply and extract ducts

SFE 2.5 kW/m

3

/s

1

2

3

4

5

6

7

8

E

E

E

E

E

E

E

E

S

S

S

S

S

S

S

S

dm

3

/s

m

3

/h

10

20

30

40

50

60

70

80

90

100

50

110

130

100

150

200

250

300

400

450

500

120

350

100

50

150

200

250

300

350

0

At a lower total pressure, SFP

will be smaller at this speed.

© VALLOX • We reserve the right to make changes without prior notification.

Air flows/DIGIT2 SE (electric radiator unit, winter setting)

Measuring points after the connection
outlet. Fan curves indicate the total
pressure available for duct losses.

VALLOX DIGIT2 SE/VKL/MLV

PERFORMANCE

3

1
2
3
4
5
6
7
8

Fan speeds

Fan input

power

W

60
80

100
120
140
160
180
230

42
67
97

130
167
205
242
315

Control

voltage

(V)

Air flows/DIGIT2 SE VKL (liquid radiator unit, winter setting)

 NOTE!
 If the unit has a post-heating
radiator, it must be selected
when the system is adjusted.

Air flow measurement outlets

The fixed air flow measurement outlets
are located behind the cover plate.
You can measure the total pressure of
the supply and extract air ductwork at
the measurement outlets using a
pressure gauge.
Compare the pressure readings with the
air volume curves to see unit air flows
at various adjustment positions.
The red measurement hose gives the
pressure reading for the supply air
ductwork and the black hose the
pressure reading for the extract air
ductwork.  Observe unit model and
setting (summer or winter).

SFP (Specific Fan Power)

guideline value < 2.5 (kW/m

3

/s) SFP = Air flow (max.) (dm

3

/s)

Input power (total) (W)

ED and SD are examples of pressure

losses in supply and extract ducts

SFP (Specific Fan Power)

guideline value < 2.5 (kW/m

3

/s)

Supply air

Extract air

S

E

ED is an example

of pressure loss

in extract ducts

Extract air flow during heat recovery bypass (summer setting)

Pressure loss in ducts. T

otal pressure Pa

Volume flow rate

dm

3

/s

m

3

/h

100

50

150

200

250

300

350

PK

dm

3

/s

m

3

/h

10

1

2

20

30

40

60

70

80

3

4

5

6

7

0

90

50

8

110

130

100

150

200

250

300

350

400

450

500

50

100

120

SD

ED

100

50

150

200

250

300

350

10

20

30

40

50

60

70

80

0

90

100

50

8E

7E

6E

5E

4E

3E

2E

1E

110

120 130

400

450

500

5S

8S

7S

6S

4S

3S

2S

1S

At a lower total pressure, SFP

will be smaller at this speed.

SFP 2.5 kW/m

3

/s

dm

3

/s

m

3

/h

SD

ED

100

150

200

250

300

350

ED

RECOMMENDED
OPERATING RANGE

RECOMMENDED
OPERATING RANGE

RECOMMENDED
OPERATING RANGE

Содержание Digit 2 SE Series

Страница 1: ...Preheating unit MLV liquid radiator Post heating unit Electric 1200 W 5 2 A Filters Supply air G3 and F7 Extract air G3 Weight 71 kg Ventilation Control panel control adjustment options Week clock co...

Страница 2: ...panel CO2 sensor option LON converter option Air flow measuring outlets behind cover plate Water radiator actuator valve Connection 12 MLV connection 10 cu 20 21 Supply air to the dwelling Extract air...

Страница 3: ...plate You can measure the total pressure of the supply and extract air ductwork at the measurement outlets using a pressure gauge Compare the pressure readings with the air volume curves to see unit a...

Страница 4: ...7 38 9 31 5 68 0 50 1 66 3 62 9 55 4 46 7 45 0 42 3 34 4 24 3 68 2 52 5 64 1 63 4 59 9 48 7 46 8 45 0 37 1 26 5 69 1 54 2 70 2 65 2 60 0 50 6 48 1 47 1 39 2 32 5 71 8 56 1 70 4 66 9 62 2 52 9 50 2 49...

Страница 5: ...dicator is not lit 1 2 3 4 5 6 7 8 Fan speed 3 Supply air temperature 21 C Post heating is on Time Filter guard alert Maintenance reminder alert Fireplace booster switch on The fireplace booster switc...

Страница 6: ...nnect them to the terminal block of the connection box by connec ting the first humidity sensor to RH1 in place of the 6K8resistor in the termi nal block remove the resistor in this ca se and the seco...

Страница 7: ...dB LWA dB A 1 16 24 2 25 47 3 36 70 4 48 90 5 58 104 6 68 116 7 75 131 8 87 148 1 25 7 2 38 7 3 46 46 4 59 69 5 72 79 6 82 106 7 92 112 8 104 141 LpA dB A AP qV dm3 s AP supply extract dm3 s ED and SD...

Страница 8: ...WITCH REMOTE MONITORING 1 10 2 3 4 5 6 7 8 9 1 10 16x0 25mm2 1 2 A 2 3 4 REMOTEMONITORING 0 10VDCor0 20mA ha ro L 6 7 FIREPLACESWITCH 6 va vi va ke R ke r r vi 7 5 7018800 2 1 N K K 1 2 r s m r 2N 1 2...

Страница 9: ...SENSOR IS CONNECTED TO REPLACE THE R6k8 RESISTOR HUMIDITY SENSOR RH1 OPTION BLACK M WHITE 2 B ORANGE 2 A WHITE 1 ORANGE 1 FAULT SIGNAL MAX 1 A 24 VDC POTENTIAL FREE CONTACTS FIREPLACE SWITCH pressure...

Страница 10: ...e loss in the valve 0 3 0 4 Liquid flow dm3 s 0 2 0 02 0 03 0 04 0 05 0 06 0 08 0 1 0 01 1 2 3 4 5 6 7 0 25 0 5 0 75 1 00 1 25 1 45 1 55 1 7 17 5 open Adjustment position Kv value Pressure loss p kPa...

Страница 11: ...s 70 dm3 s 90 dm3 s 8 10 Radiator pressure loss kPa 10 5 15 20 25 0 0 06 liquid flow dm3 s 30 0 08 0 04 0 02 0 35 Performance of VALLOX DIGIT2 SE MLV heating cooling radiator MLV RADIATOR HEATING POWE...

Страница 12: ...out prior notification CONTROL DIAGRAM ELECTRIC RADIATOR 12 Parts list VALLOX DIGIT2 SE electric radiator model TE1 Temperature sensor Exhaust air temperature Standard HR antifreeze Adjustment range 6...

Страница 13: ...henever outdoor air temperature falls below the threshold set or when outdoor air is warmer than extract air Heat recovery antifreeze The control centre of the unit controls the operation of preheatin...

Страница 14: ...reserve the right to make changes without prior notification CONTROL DIAGRAM VKL MODEL 14 Parts list VALLOX DIGIT2 SE VKL water radiator model TE1 Temperature sensor Exhaust air temperature Standard H...

Страница 15: ...e sensors TE1 and TE3 preventing the risk of freezing and the intermittent stopping of supply air fan S If the power of preheating unit R2 is not enough or is not on the control centre intermittently...

Страница 16: ...TION PANEL PLUG LON CONVERTER REMOTE MONITORING CONTROL CENTRE OF THE PROPERTY ALARM OPERATION MODE CONTROL MEASUREMENT ADJUSTMENT VENTILATION ZONE INTERNAL ELECTRICAL AND CONTROL CONNECTIONS POST HEA...

Страница 17: ...sensor Automatic Adjustment range 1 99 99 Option Humidity control Adjustment interval 1 15 min 10 10 VALLOX We reserve the right to make changes without prior notification 17 PART LIST Parts list VAL...

Страница 18: ...very antifreeze Controlling preheating in a liquid circulating MLV radiator is different from that in an electric preheating radiator The liquid radiator switches on based on the measurement data from...

Страница 19: ...straight The outdoor air duct must be insulated against condensation also between the unit and the ceiling mounting plate Installation Lift the unit straight upwards till the locking wings on the sid...

Страница 20: ...ivery Because of the risk of condensing the pump should be suitable for pumping liquid colder than the ambient temperature e g Grundfors UPS 25 60 180 model K MV Solenoid valve not included in the del...

Отзывы: