background image

5

© Vallox Oy - All rights reserved

 

INTRODUCTION

NOTE

For the MyVallox Cloud/

Home instructions, 

please go to 

vallox.techmanuals.info/

ValloxMV/ENG/help/

webhelp

IMPORTANT

Apartment-specific 

ventilation units allows 

residents to adjust the 

ventilation efficiency. 

Ventilation is controlled 

based on the need e.g. 

through the cooker 

hood, ventilation 

control panel, or a 

separate control centre. 

In order to ensure that 

the indoor air presents 

no harm to health and 

remains optimal also 

for the structures of the 

building, 

ventilation 

must be kept on 

without disruptions. 

It is recommended 

that ventilation be 

left turned on during 

long holidays also. 

This keeps the 

indoor air fresh and 

prevents humidity 

from condensing in 

the ventilation ducts 

and structures. It also 

reduces the risk of 

moisture damage. 

IMPORTANT

Prolonged overpressure 

can result in damage 

to the structures of the 

building.

VENTILATION UNIT CONTROL 

Ventilation unit control options

Operation of the Vallox ventilation unit can be controlled by the 

following means:

•  Through the My Vallox Control panel installed in the building.

•  Through the MyVallox Home local area network connection and 

the MyVallox Home/Cloud user interface.

•   Through the MyVallox Cloud service and the MyVallox Home/

Cloud user interface.

•   Through a remote monitoring service or building automation 

that uses voltage signals or Modbus messages.

In addition to the integrated humidity and carbon dioxide sensor, 

ventilation can also be adjusted automatically by using the optional 

carbon dioxide, humidity, or VOC (air quality) sensor. When these 

are used, ventilation remains optimal even when the dwelling 

is unoccupied. Each user can use the week clock to adjust the 

ventilation to fit their individual lifestyle. 

Filter reminder

The unit reminds the user of the need to change the filters through 

the MyVallox Control panel and the MyVallox Home/Cloud user 

interface, as well as by changing the relay status, if a signal light 

has been connected to the relay connectors of the unit.
The filter reminder can be acknowledged:

•  From the MyVallox Control panel

•  From the MyVallox Home/Cloud user interface

•  From the Vallox Delico PTD EC and Vallox Capto PTC EC 

control hoods 

— Damper closed, then open-closed-open-

closed. Press at a less than 1 second interval.

Ventilation unit setup without a MyVallox 

Control panel

The ventilation unit setup can also be completed without a 

MyVallox Control panel. For instructions, please go to 

https://vallox.techmanuals.info/ValloxMV/FIN/onlinehelp/webhelp

See instructions provided in the section Connecting the ventilation 

unit to the computer.

Connecting the ventilation unit to the cloud 

service

The ventilation unit can be connected to the MyVallox Cloud 

service. The cloud service allows for controlling ventilation 

remotely also, using e.g. a smartphone or tablet. Also the unit 

software is updated automatically through the cloud service. 

To connect to the cloud service, the ventilation unit must be 

connected to the Internet via LAN and registered with the cloud 

service. At the same time you create a MyVallox Cloud account for 

yourself. Read more about the service at www.myvallox.com.

Содержание A3609

Страница 1: ...l Vallox TSK Multi 50 MV Vallox TSK Multi 50 MV EH Vallox TSK Multi 80 MV Vallox TSK Multi 80 MV EH Type A3609 A3609 1 C3608 C3608 1 Document D5321 Valid from 7 3 2022 Updated 20 06 2022 Ventilation u...

Страница 2: ...nd space required for installation of the Vallox Silent Klick siphon 8 MAINTENANCE 9 Before beginning maintenance work 9 Changing the filters 9 Cleaning the heat recovery cell 10 Condensing water 10 C...

Страница 3: ...odifications or changes made to the software INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to...

Страница 4: ...result in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoided CAUTION Indicates a hazard that can result in minor o...

Страница 5: ...automatically by using the optional carbon dioxide humidity or VOC air quality sensor When these are used ventilation remains optimal even when the dwelling is unoccupied Each user can use the week cl...

Страница 6: ...act air 7 Bypass damper of the HR cell 8 R model in the figure MAIN PARTS Vallox TSK Multi 50 MV and Vallox TSK Multi 80 MV Safety switch 9 Control panel 10 Internal humidity sensor 11 Internal carbon...

Страница 7: ...ront of the unit for servicing purposes The service space in front of Vallox TSK Multi 50 MV must be at least 530 mm The service space in front of Vallox TSK Multi 80 MV must be at least 600 mm NOTE T...

Страница 8: ...239 1 935 935 547 547 L model R model R model 1 Outdoor air to the unit 2 Supply air from the unit to the apartment 3 Extract air from the apartment to the unit 4 Exhaust air flowing outdoors from the...

Страница 9: ...and dust particles out of the supply air Coarse filter for extract air filters the extract air and keeps the heat recovery cell clean To replace the filters 1 Disconnect the ventilation unit from the...

Страница 10: ...een added 10 Rinse the cell clean with a water spray Do not use a high pressure cleaner 11 When all the water has drained from between the layers reassemble the ventilation unit in the reverse order 1...

Страница 11: ...2 Unfasten the four screws to open the door of the unit 3 Lift the door off CAUTION The door is heavy 4 Remove the extract air filter C the cell top bracket E and the heat recovery cell D as described...

Страница 12: ...oving the supply air fan Figure 1 6 Remove the connector package from the wall 7 Separate the connectors from each other 8 Tilt the fan to the left and turn 90 9 Tilt the fan forward to pull it out of...

Страница 13: ...t air supply air TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS AIR FLOWS AND SOUND VALUES Pressure loss in ducts Total pressure Pa Volume flow rate dm3 s TECHNICAL SPECIFICATIONS Product title Val...

Страница 14: ...level coming through the envelope of the unit in the room in which it is installed 10m sound absorption Adjustment position Air flows supply extract Adjustment position 10 20 30 40 50 60 70 80 100 Air...

Страница 15: ...0 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 Air flow dm s 15 20 32 37 47 57 62 65 17 22 36 42 51 60 66 67 Medium frequency of the octave band Hz 63 60 67 68 72 73 79 79 78 54 58 59 63 66 78...

Страница 16: ...TSK Multi 50 MV EH Vallox TSK Multi 80 MV EH EHX R2 Additional heating resistor with 90 C and 130 C overheating protection Vallox TSK Multi 80 MV EHX BK Black BU Blue BN Brown WT White GY Grey YE Yel...

Страница 17: ...ICAL CONNECTION Analog input two different functions Potential free contact data 24VDC can be programmed to display information such as errors or to control the valve and pump of the MLV radiator Plug...

Страница 18: ...winter limit value set at the factory 5 C Cooling The supply air setpoint value for the active mode for example At home controls the pump start up The pump starts when the supply air setting is below...

Страница 19: ...alve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example Danfoss 032U161431 K Condensing water tube Not included in the delivery...

Страница 20: ...External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Local hardware Modbus B signal NTC External t...

Страница 21: ...R model Vallox TSK Multi 80 MV 942210 14 b Additional heating resistor L model Vallox TSK Multi 80 MV 942211 15 Side sealing strip of the heat recovery cell Vallox TSK Multi 50 MV 3356300 15 Side sea...

Страница 22: ...CONFORMITY CERTIFICATES...

Страница 23: ......

Страница 24: ...www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND D5321 20 06 2022FIN 20 06 2022ENG PDF...