background image

21

© Vallox Oy - All rights reserved

  NO.  PART

CODE

1. 

Frame: Vallox TSK Multi 50 MV / 80 MV

2. Door 

(Vallox TSK Multi 50 MV)

3473500

2. Door 

(Vallox TSK Multi 80 MV)

3483000

3. 

Finger screw for the door

990698

4. 

HR cell, plastic 

(Vallox TSK Multi 50 MV)

933175

4. 

HR cell, aluminium 

(Vallox TSK Multi 50 MV)

933120

4. 

HR cell, enthalpy 

(Vallox TSK Multi 50 MV)

933151

4. 

HR cell, plastic

 (Vallox TSK Multi 80 MV)

933195

4. 

HR cell, aluminium 

(Vallox TSK Multi 80 MV)

933130

4. 

HR cell, enthalpy 

(Vallox TSK Multi 80 MV)

933152

5.  Fan assembly, R and L models 

(Vallox TSK Multi 50 MV)

3473400

5.  Fan assembly, R and L models 

(Vallox TSK Multi 80 MV)

3482900

6. Fan 

(Vallox TSK Multi 50 MV)

935385

6. Fan 

(Vallox TSK Multi 80 MV)

935490

7. 

Bypass duct assembly 

(Vallox TSK Multi 50 MV R)

3432700

7. 

Bypass duct assembly 

(Vallox TSK Multi 50 MV L)

3551300

7. 

Bypass duct assembly 

(Vallox TSK Multi 80 MV R)

3479500

7. 

Bypass duct assembly 

(Vallox TSK Multi 80 MV L)

3551400

8.  Damper actuator, R model

930621

8.  Damper actuator, L model

930620

9. 

Safety switch

948370

10. Motherboard

949032-1

11.  RJ45 extension cable

952196

12.  Internal humidity and carbon dioxide sensor

4107985

13.  NTC sensor kit

3494100

14.  Post-heating resistor, R model

942210

14.  Post-heating resistor, L model

942211

EXPLODED VIEW 

AND PARTS LIST 

TECHNIC

AL SPECIFIC

ATIONS

13

12

11

10

14

20

21

9

18

2

3

4

17

16

19

15

1

14b

8

7

5

6

24

22 23

26

27

25

28
29

30

  NO.  PART

CODE

14 b.  Additional heating resistor, R model 

(Vallox TSK Multi 80 MV) 

942210

14 b.  Additional heating resistor, L model 

(Vallox TSK Multi 80 MV) 

942211

15.  Side sealing strip of the heat recovery cell 

(Vallox TSK Multi 50 MV)

3356300

15.  Side sealing strip of the heat recovery cell 

(Vallox TSK Multi 80 MV)

3352600

16.  Upper sealing strip of the heat recovery cell 

(Vallox TSK Multi 50 MV)

3463400

16.  Upper sealing strip of the heat recovery cell 

(Vallox TSK Multi 80 MV)

3488700

17.  Filter stand 

(coarse filter for supply air, 500 mm, Vallox TSK Multi 50 MV))

3356400

17.  Filter stand 

(coarse filter for supply air, 580 mm, Vallox TSK Multi 80 MV))

3352700

18.  Filter stand 

(coarse filter for extract air, 400 mm, Vallox TSK Multi 50 MV))

3382800

18.  Filter stand 

(coarse filter for extract air, 450 mm, Vallox TSK Multi 80 MV))

3368500

19.  Coarse filter for supply air (Vallox TSK Multi 50 MV)

978036

19.  Coarse filter for supply air (Vallox TSK Multi 80 MV)

3326700

20.  Coarse filter for extract air (Vallox TSK Multi 50 MV)

978035

20.  Coarse filter for extract air (Vallox TSK Multi 80 MV)

3379700

21.  Fine filter for supply air (Vallox TSK Multi 50 MV)

978136

21.  Fine filter for supply air (Vallox TSK Multi 80 MV)

978135

22. Plug 

(Vallox TSK Multi 50 MV)

990630

22. Plug 

(Vallox TSK Multi 80 MV)

990640

23.  Cover panel 100mm 

(Vallox TSK Multi 50 MV)

3363500

23.  Cover panel 125mm 

(Vallox TSK Multi 80 MV)

3363600

24.  Siphon Vallox Silent Klick

3494701

25.  MyVallox Control panel

949033

26.  Connection box assembly

3526700

27.  MyVallox humidity sensor 

(optional)

946149

28.  MyVallox carbon dioxide sensor 

(optional)

949111

29.  MyVallox VOC sensor (optional)

 949112

30.  Glass tube fuse 63mA slow 5x20mm

952490

Содержание A3609

Страница 1: ...l Vallox TSK Multi 50 MV Vallox TSK Multi 50 MV EH Vallox TSK Multi 80 MV Vallox TSK Multi 80 MV EH Type A3609 A3609 1 C3608 C3608 1 Document D5321 Valid from 7 3 2022 Updated 20 06 2022 Ventilation u...

Страница 2: ...nd space required for installation of the Vallox Silent Klick siphon 8 MAINTENANCE 9 Before beginning maintenance work 9 Changing the filters 9 Cleaning the heat recovery cell 10 Condensing water 10 C...

Страница 3: ...odifications or changes made to the software INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to...

Страница 4: ...result in death or serious injury if not avoided IMPORTANT Indicates a hazard that can result in damage to property or loss of data if not avoided CAUTION Indicates a hazard that can result in minor o...

Страница 5: ...automatically by using the optional carbon dioxide humidity or VOC air quality sensor When these are used ventilation remains optimal even when the dwelling is unoccupied Each user can use the week cl...

Страница 6: ...act air 7 Bypass damper of the HR cell 8 R model in the figure MAIN PARTS Vallox TSK Multi 50 MV and Vallox TSK Multi 80 MV Safety switch 9 Control panel 10 Internal humidity sensor 11 Internal carbon...

Страница 7: ...ront of the unit for servicing purposes The service space in front of Vallox TSK Multi 50 MV must be at least 530 mm The service space in front of Vallox TSK Multi 80 MV must be at least 600 mm NOTE T...

Страница 8: ...239 1 935 935 547 547 L model R model R model 1 Outdoor air to the unit 2 Supply air from the unit to the apartment 3 Extract air from the apartment to the unit 4 Exhaust air flowing outdoors from the...

Страница 9: ...and dust particles out of the supply air Coarse filter for extract air filters the extract air and keeps the heat recovery cell clean To replace the filters 1 Disconnect the ventilation unit from the...

Страница 10: ...een added 10 Rinse the cell clean with a water spray Do not use a high pressure cleaner 11 When all the water has drained from between the layers reassemble the ventilation unit in the reverse order 1...

Страница 11: ...2 Unfasten the four screws to open the door of the unit 3 Lift the door off CAUTION The door is heavy 4 Remove the extract air filter C the cell top bracket E and the heat recovery cell D as described...

Страница 12: ...oving the supply air fan Figure 1 6 Remove the connector package from the wall 7 Separate the connectors from each other 8 Tilt the fan to the left and turn 90 9 Tilt the fan forward to pull it out of...

Страница 13: ...t air supply air TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS AIR FLOWS AND SOUND VALUES Pressure loss in ducts Total pressure Pa Volume flow rate dm3 s TECHNICAL SPECIFICATIONS Product title Val...

Страница 14: ...level coming through the envelope of the unit in the room in which it is installed 10m sound absorption Adjustment position Air flows supply extract Adjustment position 10 20 30 40 50 60 70 80 100 Air...

Страница 15: ...0 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 Air flow dm s 15 20 32 37 47 57 62 65 17 22 36 42 51 60 66 67 Medium frequency of the octave band Hz 63 60 67 68 72 73 79 79 78 54 58 59 63 66 78...

Страница 16: ...TSK Multi 50 MV EH Vallox TSK Multi 80 MV EH EHX R2 Additional heating resistor with 90 C and 130 C overheating protection Vallox TSK Multi 80 MV EHX BK Black BU Blue BN Brown WT White GY Grey YE Yel...

Страница 17: ...ICAL CONNECTION Analog input two different functions Potential free contact data 24VDC can be programmed to display information such as errors or to control the valve and pump of the MLV radiator Plug...

Страница 18: ...winter limit value set at the factory 5 C Cooling The supply air setpoint value for the active mode for example At home controls the pump start up The pump starts when the supply air setting is below...

Страница 19: ...alve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example Danfoss 032U161431 K Condensing water tube Not included in the delivery...

Страница 20: ...External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Local hardware Modbus B signal NTC External t...

Страница 21: ...R model Vallox TSK Multi 80 MV 942210 14 b Additional heating resistor L model Vallox TSK Multi 80 MV 942211 15 Side sealing strip of the heat recovery cell Vallox TSK Multi 50 MV 3356300 15 Side sea...

Страница 22: ...CONFORMITY CERTIFICATES...

Страница 23: ......

Страница 24: ...www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND D5321 20 06 2022FIN 20 06 2022ENG PDF...

Отзывы: