background image

© VALLOX • We reserve the right to make changes without prior notification.

CONTROL METHODS

5

VALLOX 75/95 SILENT

In winter use

  the heat recovery cell of VALLOX 75 and VALLOX 95 recovers heat from the

air leaving the dwelling and uses it to heat the air coming from the outside.

Electric radiator

VALLOX 75 / 95 units feature a 500 W post-heating radiator.The temperature of supply
air is adjusted at the thermostat regulatorlocated inside the unit.Adjustments can be made
within the range of 0...25

°

C.

POST-HEATING

In summer use

 the heat recovery cell is bypassed in VALLOX 75 and VALLOX 95 with anin-

built damper.

In the summer position airflow through the cell is prevented, and heat recovery bypass is
activated.

REMOTE MONITORING CENTRE VALLOX 1993A

• ON/OFF switch
• Operating status data to remote monitoring
• Transformer with eight voltage options,

of which two + one preselected

• Can be controlled with a timer or through

remote monitoring, for example.

Depth:

100 mm

Height:

180 mm

Width:

255 mm

SEPARATE CONTROL CENTRE 1992A 0.85 A

Depth: 90 

mm

Height: 140 

mm

Width: 110 

mm

• 4-step adjustment
• ON/OFF switch

SEPARATE CONTROL CENTRE 1992A EK 0,85 A

Depth:

90 mm

Height:

140 mm

Width:

110 mm

• Separate 4-step adjustment switch
• ON/OFF switch

COOKER HOOD PTX/PTXP(A) 500/600 0,85 A

Depth:

500 mm

Height:

140 mm

Width:

498/598 mm

• Washable grease filter, easy to remove
• Bright, long lasting fluorescent lamp
• Outlet collar with rubber ring

HEAT RECOVERY BYPASS

Содержание 75 SILENT

Страница 1: ...changer efficiency approx 60 Summer winter damper Electric 500 W radiator or water radiator VKL G 3 F 7 G 3 52 kg Door switch Cooker hood PTX PTXP control centre 1992 1992 EK or remote monitoring cont...

Страница 2: ...welling 4 3 2 1 VALLOX 75 95 SILENT DIMENSIONS AND MAIN PARTS 2 2 Main parts Extract air fan Supply air fan Postheating radiator electric or water Heat recovery cell Outdoor air filter F7 1 2 3 5 4 6...

Страница 3: ...OX 75 95 SILENT Pressure loss in ducts Total pressure SFP Specific Fan Power guideline value 2 5 kw m3 s SFP Input power total W Air flow max dm3 s Pressure loss in ducts Total pressure SFP Specific F...

Страница 4: ...52 53 55 28 36 44 47 51 53 54 20 30 39 42 45 47 49 19 33 37 41 43 44 76 79 83 85 89 90 89 50 54 60 62 65 67 68 61 67 73 74 79 78 80 53 61 67 69 72 74 75 41 48 57 60 63 65 67 29 32 39 42 44 46 47 22 3...

Страница 5: ...summer position airflow through the cell is prevented and heat recovery bypass is activated REMOTE MONITORING CENTRE VALLOX 1993A ON OFF switch Operating status data to remote monitoring Transformer...

Страница 6: ...he flow of outdoor air to the unit The unit starts automatically as soon as the risk of freezing has passed The threshold temperature of the risk of freezing can be set at the thermostat J of the wate...

Страница 7: ...the front edge of the damper below the front edge of the collar When detaching the damper take the same steps in the opposite order Self actuated one way dampers are only used in VKL model units B C D...

Страница 8: ...of the electric radiator The overheat protector T2 of the radiator R is triggered and power supply to the heating unit is stopped if the temperature of the thermostat exceeds 80 C The overheat protect...

Страница 9: ...stops the unit when the temperature of water radiator goes below the threshold value preventing the risk of freezing in the water radiator This also causes self actuated one way dampers SP to close p...

Страница 10: ...1 L L N L 3 2 N INTERNAL ELECTRICAL CONNECTION OF THE HOODS N L VALLOX 95 75 COOKER HOOD PTXP A 27983 COOKER HOOD PTX 27983 HOOD Distribution panel L3 230 V 160 V 120 V 70 V L N 90 V 135 V 180 V 1 5...

Страница 11: ...internal electrical connection F1 Supply air fan F2 Extract air fan T1 Post heating radiator regulating thermostat 0 25 C Limitation T2 Defrost thermostat 5 C K Capacitor SS Safety switch Wire colour...

Страница 12: ...LENT 12 ELECTRICAL CONNECTIONS REMOTE MONITORING VALLOX 75 95 control through remote monitoring with control centre 1993 YK 2A VALLOX 1993A YK 2A VALLOX 75 95 REMOTE MONITORING CONTROL CENTRE DISTRIBU...

Страница 13: ...plate has to be fixed horizontally in order to ensure that the unit will be straight The outdoor air duct must be insulated against condensation also between the unit and the ceiling mounting plate S...

Страница 14: ...he pipe and its components Examples of condensing water connections Yli 600 n 100 n 100 Suction air COLLECTOR condensing water goes to the cellar Water seal at the lower end n 100 Suction air and fill...

Отзывы: