background image

12

Vallox

096

SE

© VALLOX • We reserve the right to make changes without prior notice.

What the units include can vary depending on the sales area.

TECHNICAL DATA

2

NOMAK 2x2x0,5+0,5

1

2

1

S

+

A

2x0.5

+

2x0.5

A

+

MAX. 1A, 24VDC

-

B

M

0-10V DC 

S

+

-

B

M

0...10VDC 

2x0.5

2x0.5

A

2x0.5

B

-

+

M S

+

S

+

+

1

2

S

S

GND

%RH1

%RH2

7010101

2011-09-12 pl

0-20mA

R

Mounting, removing and wiring of the control panel

The control panel is wired straight from the electrical connection box. 

The control panel can also be connected in series with a CO

2

 sensor or 

another control panel. (See External electrical connection).

Control panel addresses

If two or more control panels are connected to the system, the addresses 

of the control panels need to be changed.

For example 3 control panels

 

• Connect the fi rst control panel to the unit and change its address to 3.
• Connect the second control panel to the unit and change its address 

to 2.
• Connect the third control panel and make sure that its address is 1.
If control panels have the same address, they go to bus fault state. In this 

case, remove one of the control panels and change the address of the 

other panel. The above mentioned situation can arise in connection with 

the later installation of an additional control panel.

External electrical 
connection 
Vallox 096 SE 

(code 3720)

METAL  

= M

WHITE 2 

= B

ORANGE 2 

= A

WHITE 1 

= -

ORANGE 1 

= +

2. TWISTED PAIR
1. TWISTED PAIR

NOTE!

Faulty connection of 

the + wire DESTROYS 

CONTROL PANEL

NOTE!

Faulty connection of the + 

wire DESTROYS THE SENSOR

CONTROL PANEL 1 

ONE OR MORE 

1 INCLUDED AS STANDARD

CO

2

 SENSOR 1 

ONE OR MORE 

OPTION

REMOTE MONITORING

SHORT-CIRCUIT WIRE HAS TO BE 

REMOVED BEFORE CONNECTION

FIREPLACE 

SWITCH

Button switch

(self-resetting contact)

(POTENTIAL-FREE CONTACTS)

THE FIRST HUMIDITY SENSOR 

IS CONNECTED TO REPLACE 

RESISTOR R6k8

HUMIDITY SENSOR %RH2 

OPTION

HUMIDITY SENSOR %RH1 

OPTION

FAULT SIGNAL

FAULT SIGNAL

RS-485 BUS

FIREPLACE SWITCH

FAN CONTROL

PLUG CONNECTION 10 A  

1.2 m ON TOP OF THE UNIT

If the mains connection cable becomes 

damaged, it must be replaced by the 

manufacturer, an authorised maintenance 

company or other qualifi ed person in order 

to avoid danger.

CONNECTION BOX IS SITUATED 

ON TOP OF THE UNIT

CONNECTION BOX INSIDE 

THE UNIT

Width   90 mm
Height  110 mm
Depth  23 mm

Содержание 096 SE L

Страница 1: ...erating maintenance and technical instructions Electrical connection 230 V 50 Hz 5 1 A plug Degree of protection provided by enclosures IP 34 Fans Extract air 89 dm3 s 100 Pa direct current DC Supply...

Страница 2: ...ring result 1 to 2 carbon dioxide sensors can be connected as options to the VALLOX 096 SE unit The adjustment is switched on off and if needed the setpoint 500 2000 ppm is set at the control panel Th...

Страница 3: ...heating indicator light Maintenance reminder symbol Maintenance reminder The maintenance reminder switches on the maintenance reminder symbol on the main display of the control panel at defined interv...

Страница 4: ...menu you can change setpoints for the ventilation unit 2 3 Week clock control Week program on Week clock control can be switched on with the button and off with the button Week clock control is on wh...

Страница 5: ...water or electric radiator is selected with the and buttons depending on the type of post heating radiator the unit is equipped with Note Choosing the wrong type of post heating may cause a faulty pos...

Страница 6: ...ttons The rotation speed of the extract air fan can be decreased by decreasing the percentage Move the cursor with the arrow keys and change values with the and buttons Note that to exit and save when...

Страница 7: ...By using original Vallox filters you ensure good operation of the ventilation unit and the best filtering result The replacement interval of filters depends on dust content in ambient air It is recomm...

Страница 8: ...you wish to detach the fan lift it upwards and crank the plastic lock to the right using for instance a chisel gure 6 The fan then falls down and can be pulled out of the unit Disconnect the quick co...

Страница 9: ...t message is displayed and the unit operates at speed 1 check the fan speed Wiring fault in the carbon dioxide sensor in the control panel or in the humidity sensor or the cable is of the wrong type C...

Страница 10: ...ing range E Extract air fan S Supply air fan Input power total W Air flow max dm3 s SFP SFP Specific Fan Power recommended value 2 5 kW m3 s At a lower total pressure SFP will be smaller at this speed...

Страница 11: ...P W M 5 4 3 2 1 M 2x0 25 3x0 25 BN WT BN GN connection box on top of the unit 5 3 10 1 FAN CONTROL 0 10 V DC A B M S S 1 2 S S RH1 RH2 RS 485 BUS FAULT SIGNAL FIREPLACE SWITCH 12x0 25mm2 N GND L1 L 1...

Страница 12: ...t state In this case remove one of the control panels and change the address of the other panel The above mentioned situation can arise in connection with the later installation of an additional contr...

Страница 13: ...t protective enclosure the unit must be located in a place with no acoustic disturbance storerooms technical rooms etc Wall mounting VALLOX 096 SE is mounted on the wall with a mounting plate as shown...

Страница 14: ...ting plate in place Then 4 332 544 600 600 push a rubber damper and washer to each thread bar all the way into the cup of the plate and turn the nut Shorten the lower ends of the thread bars so that t...

Страница 15: ...l 3467200 10 Filter stand 3464500 No Part Code 11 G4 coarse filter 978045 extract air 12 Bypass duct assembly 3475100 indicate if right or left handed 13 Damper motor 930613 14 Extract air outlet 9850...

Страница 16: ...1 09 602E 3 12 2013 PDF...

Отзывы: