background image

VALLEY COMFORT SYSTEMS INC. 

1290 COMMERCIAL WAY, PENTICTON, B.C.   V2A 3H5  --   PHONE: (250) 493-7444 

PAGE 

2

 

 
 

Welcome  to  the  discriminating  group  of  Canadian  home  owners  who  have  selected 
Valley Comfort heating units to satisfy their home heating needs. 
 
The  product  you  have  bought  was  made  by  skilled  craftsmen  who  have  given  the 
company  an  experience  of  over  forty  years  in  providing  domestic  heating  appliances.  
Your  heating  unit  has  been  tested  to  meet  rigorous  safety  standards  by  a  certified 
independent testing laboratory. 
 
This booklet contains the operating and installation instructions.  Unless the installation 
instructions  are  followed  completely  Valley  Comfort  cannot  honour  its  warranty 
obligations to you, the owner.  Also, unless the installation instructions are followed, you 
will not be getting the best results from your unit. 
 
 
"SAFETY  NOTICE:    IF  THIS  HEATER  IS  NOT  PROPERLY  INSTALLED,  A  HOUSE 
FIRE  MAY  RESULT.    FOR  YOUR  SAFETY,  FOLLOW  THE  INSTALLATION 
DIRECTIONS.    CONTACT  LOCAL  BUILDING  OR  FIRE  OFFICIALS  ABOUT 
RESTRICTIONS  AND  INSTALLATION  INSPECTION  REQUIREMENTS  IN  YOUR 
AREA." 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание VC95C

Страница 1: ...SOLID FUEL FIRED HEATER INSTALLATION AND OPERATION MANUAL READ THOROUGHLY AND COMPLY WITH ALL LOCAL CODES AND REGULATIONS VALLEY COMFORT SYSTEMS INC 1290 COMMERCIAL WAY PENTICTON B C V2A 3H5 250 493...

Страница 2: ...c Damper 6 Blower 3 Chimney 5 6 8 9 10 Combustible Materials 5 Creosote 9 10 Door Handle 7 Fan 5 6 Flue 5 8 Fuel 1 4 6 7 8 9 10 Handy Hints 10 Important 8 Installation Instructions 5 Minimum Installat...

Страница 3: ...to meet rigorous safety standards by a certified independent testing laboratory This booklet contains the operating and installation instructions Unless the installation instructions are followed comp...

Страница 4: ...imitations on how long implied warranty lasts so the above limitation may not apply to you Actions for breach of this warranty must be brought within one 1 year of the expiration of this warranty HOW...

Страница 5: ...such as artificial logs wood exposed to salt water or coal that may burn at excessively high temperatures or may release fumes that can explode will VOID this warranty Burning the heater with the load...

Страница 6: ...must be made to compensate for air drawn from the area by other appliances such as exhaust fans clothes dryers or fireplaces If the heater is being installed where normal air infiltration does not mee...

Страница 7: ...8 tile lined masonry chimney which is in good repair and free from any leaks or obstructions Alternately a 6 diameter prefabricated chimney approved for solid fuel can be used NOTE Care should be take...

Страница 8: ...n the heater and cover them with kindling and small pieces of wood Ignite this and as the fire grows add larger pieces of wood Do not be alarmed by fuming or smoke the first time you use your heater T...

Страница 9: ...eather conditions will determine the firing rate DURING MILD WEATHER When the temperature is warmer you only need to add enough of the driest wood available to last four to six hours This will cut dow...

Страница 10: ...the flue pipe and chimney become coated because of operation under improper conditions the only practical way of cleaning is to disassemble the pipe and clean it and the chimney by scraping The best...

Страница 11: ...hen adding fuel to protect the floor covering Smoke discharged into the room when the fuel charging door is opened usually indicates that the previous charge has not completely charred or that there i...

Отзывы: