FP15 & FP15A Waterloo - Installation and Operation Manual
61
7.8.2
Universal Offset Support
This support is used to support the chimney above an offset. When the chimney offset is used to pass
through a wall, this support may be used on the wall to support the chimney. For offset support installation,
refer to the instructions provided with the support by the chimney manufacturer. Many manufacturers will
provide the maximum height of chimney that can be supported by the support. Make sure you respect
those parameters.
7.9
Installation Instructions for Masonry Application
WARNING
BEFORE STARTING THE INSTALLATION, THE MASONRY CHIMNEY MUST BE INSPECTED BY A QUALIFIED
CHIMNEY SWEEPER.
The following requirements must be respected:
1.
The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing
bricks that could inhibit correct installation of the liner.
2.
The clearance to combustible must be a minimum of 1" between the outside of the masonry and any
wood framing or loose insulation.
3.
The chimney must be built in accordance with the current building code.
4.
No other appliance can be connected to the same chimney.
NOTE
•
THE CHIMNEY MUST BE RELINED WITH A STAINLESS STEEL LINER OF THE SAME DIAMETER AS THE
OUTLET OF THE FIREPLACE.
•
FOR CONNECTION AT 30° OR 45° ANGLE (30° OR 45° IN CANADA AND 30° ONLY IN THE USA), A
SPECIAL CONNECTOR MUST BE USED TO CONNECT THE LINER TO THE INSULATED CHIMNEY. VERIFY
AVAILABILITY AND INSTALLATION INSTRUCTIONS FOR THIS CONNECTOR WITH THE CHIMNEY
MANUFACTURER.
7.9.1
Installation instructions
1.
Position the fireplace in its location. Temporarily install the elbow
or chimney section
(A)
on the top of the fireplace and, using a level,
mark with an oval the location where the flue liner will enter the
masonry chimney.
2.
In the middle of the oval, drill a hole in the masonry chimney at 45
°
or 30
°
.
3.
Increase the size of the hole until a 45
°
or 30
°
insulated liner
adapter
(B)
can be easily slipped through.
4.
Slide the liner
(C)
down from the top of the masonry chimney until
you reach the hole level.
5.
Slip through the hole a 45
°
or 30
°
insulated liner adapter and
connect it to the liner.
Содержание Waterloo
Страница 2: ...2 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 11: ...FP15 FP15A Waterloo Installation and Operation Manual 11 2 3 Measurements FP15 ...
Страница 12: ...12 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 13: ...FP15 FP15A Waterloo Installation and Operation Manual 13 2 4 Measurements FP15A ...
Страница 14: ...14 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 78: ...78 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 79: ...FP15 FP15A Waterloo Installation and Operation Manual 79 APPENDIX 9 EXPLODED DIAGRAM AND PARTS LIST FP15 ...
Страница 83: ...FP15 FP15A Waterloo Installation and Operation Manual 83 APPENDIX 10 Exploded Diagram and Parts List FP15A ...
Страница 88: ......