FP15 & FP15A Waterloo - Installation and Operation Manual
23
4.3.5
Shutting Down the Air Supply
The fireplace can operate at three different settings: Maximum combustion rate, medium combustion rate
and finally low combustion rate. At the low combustion rate setting, the fireplace is operated with an air
control system that regulates the combustion.
The maximum combustion rate setting is usually for cold startup and when maximum heat is desired
(Position A).
At the maximum combustion rate setting, the air control system is not operating.
NOTE
THE AIR CONTROL SYSTEM IS ACTIVATED ONLY WHEN THE AIR INTAKE IS COMPLETLY CLOSED
(POSITION B) AND WHEN THE FIREPLACE IS HOT ENOUGH.
When you close the air intake, you gradually reduce the combustion. Visually you will be able to notice a
considerable reduction of combustion. Under these conditions, you will be at the medium combustion rate.
Using the secondary air intake lever you can adjust your combustion system to eventually reach the
minimum combustion rate.
If the flames diminish to the point of disappearing when you reduce the air supply, your wood can be too
humid. If you have seasoned wood and use the air intake control properly, the flames should decrease, but
remain strong and stable, even when operating at low combustion rate.
Position A:
In this position, air supply is fully
open. You should be using this position for:
•
Cold start;
•
Maximum burn rate;
Position B:
Air control intake is closed
.
The air
control system is activated.
Position B1
: Low combustion rate.
Position B2
: Medium combustion rate
Example of operating sequence:
A:
Cold start or Maximum burn rate.
B:
Mid-High until the factory setting
temperature is reached.
B-2 or B-1:
Mid-Low or Low once the factory
setting is reached.
Содержание Waterloo
Страница 2: ...2 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 11: ...FP15 FP15A Waterloo Installation and Operation Manual 11 2 3 Measurements FP15 ...
Страница 12: ...12 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 13: ...FP15 FP15A Waterloo Installation and Operation Manual 13 2 4 Measurements FP15A ...
Страница 14: ...14 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 78: ...78 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 79: ...FP15 FP15A Waterloo Installation and Operation Manual 79 APPENDIX 9 EXPLODED DIAGRAM AND PARTS LIST FP15 ...
Страница 83: ...FP15 FP15A Waterloo Installation and Operation Manual 83 APPENDIX 10 Exploded Diagram and Parts List FP15A ...
Страница 88: ......