E.  Do not abuse the unit by burning paper, or cardboard or construction material such as 

pressed wood, plywood or lumber. 

F.  Do not allow the wood to smoulder or burn without flame, since this will produce 

excessive creosote in the unit. 

2.3  MAINTAINING YOUR FP 10

 

2.3.1 Creosote – Formation and need for removal 

 
When wood is burned slowly without a flame, it produces tar and other organic vapours 
which combine with expelled moisture to form creosote. The creosote vapours condense in 
the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue 
accumulates on the flue lining. When ignited this creosote makes an extremely hot fire. 
The chimney shall be inspected at least twice a year during the heating season to determine 
when a creosote build-up has occurred.  
When creosote has accumulated it shall be removed to reduce the risk of a chimney fire. 
 

2.3.2 Chimney Maintenance 

 
Regular chimney inspection and maintenance combined with proper operation will prevent 
chimney fires. Keep your chimney clean. Do not allow more than 1/16

 creosote build up in 

your chimney. The amount of creosote will depend on variables such as frequency of use and 
type of fire. We recommend that you: 

A.

 

Initially inspect the chimney system weekly. From this, you will learn how often it 
will be necessary to clean your chimney. 

B.

 

Have your chimney cleaned by a qualified chimney sweep. If you wish to clean it 
yourself, we recommend using a stiff plastic or non-metallic brush. If a metal brush is 
used, its size should be slightly smaller than the flue to avoid damaging the chimney. 
Do not use a brush that will scratch the stainless steel interior of the chimney. 

C.

 

Do not expect chemical cleaners to keep your chimney clean. The rain cap can be 
removed for inspection and/or cleaning of the chimney. 

 

2.3.3  Fire Baffle Removal Prior to Cleaning the Chimney 

 
Before starting to clean your chimney, we recommend that you remove the fire baffle to 
avoid creosote dust collection on top of the baffle. Follow the steps below to remove the fire 
baffle: 

1.

 

Remove the front air tube by pulling out the cutter pin on the side of the tube. They 

are located at the top, underneath the baffle. 

 

 

 

Содержание FP10 Lafayette

Страница 1: ...e Stove Builder International SBI will not be responsible for damages Install the fireplace only as described in these instructions PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE Listed to standards U...

Страница 2: ...imney not long enough 10 F Poor chimney draft 10 2 3 MAINTAINING YOUR FP 10 11 2 3 1 Creosote Formation and need for removal 11 2 3 2 Chimney Maintenance 11 2 3 3 Fire Baffle Removal Prior to Cleaning...

Страница 3: ...ATION INSTRUCTIONS 40 3 3 OFFSET CHIMNEY INSTALLATION 42 3 4 ANGLED WALL RADIATION SHIELD 46 3 5 CHIMNEY SUPPORT INSTALLATION 46 3 6 CHIMNEY CHASE AND MULTIPLE TERMINATIONS 47 3 7 INSTALLATION INSTRUC...

Страница 4: ...l Training or in Quebec by APC Association des Professionnels du Chauffage CAUTION THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED...

Страница 5: ...PLACE IN THAT CASE A CEMENT BOARD DUROCK STYLE IS MANDATORY FAILING TO RESPECT THIS GUIDELINE MAY RESULT IN A FIRE CAUTION DO NOT INSTALL THIS FIREPLACE IN A MOBILE HOME PLEASE NOTE THAT THE PICTURES...

Страница 6: ...to follow these instructions will void the certification and the warranty of the fireplace and may result in an unsafe installation This heating unit must serve as a supplementary heat source An alter...

Страница 7: ...he unit a fire or even possibly igniting a chimney fire if the chimney is creosoted CAUTION DO NOT OVER FIRE THIS HEATER OVER FIRING CAN RESULT IN A SAFETY HAZARD AND CAN PERMANENTLY DAMAGE THE FIREPL...

Страница 8: ...ll ignited CAUTION PLACE THE WOOD LOGS FAR ENOUGH FROM THE GLASS TO ALLOW PROPER PRIMARY AIR FLOW 2 2 5 Maintaining the Fire Once the wood has been consumed or partially consumed and you have obtained...

Страница 9: ...er if not already included is highly recommended to maximize your unit s efficiency 2 2 6 Primary Air There is no flue damper in the FP 10 As in common with air tight stoves the combustion air control...

Страница 10: ...U per hour and the loading time will be about every 3 4 hours Softwoods may be burned using this method but the time will be substantially reduced Slow Combustion When the air combustion control is co...

Страница 11: ...installed with offsets the minimum system height is 15 feet 4 6 m to 17 feet 5 2 m as per Table 1 Additional height will increase draught and will decrease the tendency to smoke If only the minimum c...

Страница 12: ...chimney fires Keep your chimney clean Do not allow more than 1 16 creosote build up in your chimney The amount of creosote will depend on variables such as frequency of use and type of fire We recomm...

Страница 13: ...ent 4 If possible use a dry chemical fire extinguisher baking soda or sand to control the fire Do not use water as it may cause a dangerous steam explosion 5 Check outside to ensure that sparks and ho...

Страница 14: ...the refractory should be replaced To replace the refractory bricks follow these steps 1 Remove the andiron A held in place by the two torx screws B 2 Remove the brick retainers C 3 Remove the left si...

Страница 15: ...to keep the glass clean under normal operating conditions If the FP 10 is operated continuously with the combustion air controls closed the glass will tend to get dirty unless the fuel firebox and gla...

Страница 16: ...by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the heart extension and the mantel and taking into...

Страница 17: ...hearth extension floor area must extend at least 18 40 cm in front of the hearth and at least 8 20 cm on each side of the door opening see figure 7 The joint between the hearth extension and the firep...

Страница 18: ...floor protection 2 4 2 1 R Calculations There are two ways to calculate the R factor of the floor protection First by adding the R values of the proposed materials or if some K and thickness values ar...

Страница 19: ...s K 1 0 75 1 33 2 4 2 2 How to eliminate the need of a R value It is however possible to eliminate the R value by elevating the unit from 4 above the floor see Figure 9 but the joint between the exten...

Страница 20: ...replace running from floor to ceiling see figure 14 Position the studs back from the front edge of the fireplace a space the thickness of the facing material so that the facing can be installed flush...

Страница 21: ...20 Figure 10 Figure 11...

Страница 22: ...21 Figure 12 Figure 13...

Страница 23: ...22 Figure 14...

Страница 24: ...ls such as brick stone or ceramic tile may project in front of and onto the fireplace decorative frame Caution Materials must be installed so that the faceplate may be removed after the installation T...

Страница 25: ...24 Figure 16...

Страница 26: ...igure 17 in order to facilitate installation However the minimum depth of the shelf is 6 or less If the depth of the shelf is not listed in the table add 52 to the depth of your shelf to obtain the sa...

Страница 27: ...26 Figure 18...

Страница 28: ...to the terminal block making sure that the white wire matches the white wire on the terminal Connect the black wire with the black wire of the terminal block The ground green or skinned wire must be...

Страница 29: ...r as shown on figure 20 c Put the faceplate back into place Figure 20 Figure 21 The safety rules for hot air ducting gravity kit installations are the following Minimum height 68 1 7 m Maximum length...

Страница 30: ...cting the following 1 Remove the plates closing up the 8 dia holes on top of the fireplace Then cut the insulation in order to obtain two 8 dia openings Insert the ducting into each opening and fix it...

Страница 31: ...h the louvers pointing downwards in order to prevent overheating adjacent ceilings 11 Always install the two outlet grilles when using the hot air outlet kit and blocking the upper louver of the firep...

Страница 32: ...ections to the PC Board as explained with the forced air kit owner s manual Since the forced air kit requires electricity make sure that the connections to the fan have been made according to the loca...

Страница 33: ...exhaust fumes gas meter and other vents E The outside termination may be installed above or below floor level F If more fresh air is needed airtight house or conduit exceeding 10 ft or 3 m two intakes...

Страница 34: ...e left side as in figure 29 to secure the plate 3 Select which air inlet you wish to use figure 30 you may use more than one and either remove the cover figure 31 side inlet or remove the knock out bo...

Страница 35: ...need to lift the gasket slightly It is important that the gasket stays intact 2 8 DOOR ALIGNMENT To adjust the door positioning and spacing loosen the hinge screw and pivot the hinge until the door i...

Страница 36: ...the hinges screws Adjust the pressure on the gasket using the centre adjustment screw located at the bottom of the combustion chamber To check the pressure applied place a slip of paper between the d...

Страница 37: ...f the fire screen against the top door opening making sure to insert the top fire screen bracket behind the primary air deflector as in DETAIL A Lift the fire screen upwards and push the bottom part t...

Страница 38: ...the fireplace is 9 ft 2 75 m for 2 Solid Pack Chimney and 12 ft 3 7 m for 1 Solid Pack Chimney 6 The chimney must extend at least 3 ft 92 cm above its point of contact with the roof and at least 2 ft...

Страница 39: ...38 Figure 36a Figure 36b...

Страница 40: ...he chase enclosure and at least 2 ft 61 cm higher than any wall roof or building within 10 ft 3 1 m of it See Figure 36c and 36d to determine the configuration that applies to your roof flat or sloped...

Страница 41: ...chimneys you must use an anchor plate supplied by the chimney manufacturer before installing the first chimney length see figure 38 Continue installing chimney lengths making sure to lock each length...

Страница 42: ...41 8 When a ventilated roof flashing is installed precautions are to be taken not to caulk or seal the ventilating openings EXAMPLE OF TYPICAL CHIMNEY INSTALLATION Figure 38...

Страница 43: ...himney lengths together according to the chimney manufacturer s instructions In many cases it is recommended to use three 3 12 mm screws If the offset length is made of two 2 chimney lengths or more m...

Страница 44: ...43 Figure 40 Figure 41...

Страница 45: ...kirk Hart Cooley TLC 1 Solid Pack 6 15 cm Selkirk Sure Temp ST 1 Solid Pack 6 15 cm Selkirk CF Sentinel CF 2 Solid Pack 6 15 cm Selkirk Super Pro 2100 ALT 2 Solid Pack 6 15 cm Selkirk Super Vent 2100...

Страница 46: ...4 Ultra Temp UT Super Pro SPR Super vent JSC Hart Cooley TLC Sure Temp ST Security Chimney Rafter protector at the roof level if chimney is enclosed at the attic level see section 4 Requires insulate...

Страница 47: ...he home s thermal barrier INSULATED WALL GYPROC INSULATED WALL RADIATION SHIELD Figure 43 3 5 CHIMNEY SUPPORT INSTALLATION Universal Roof Support This support has three possible uses 1 It must be used...

Страница 48: ...you respect those parameters 3 6 CHIMNEY CHASE AND MULTIPLE TERMINATIONS For the purpose of this manual a chimney chase is considered a part of the chimney system rather than part of a building The te...

Страница 49: ...o the insulated chimney Verify availability and installation instructions for this connector with the chimney manufacturer Follow these steps 1 Position the fireplace in its location Temporarily insta...

Страница 50: ...adapter 3 pipe clamps AC01310 And one control box with heat sensor and PC Board Rigid spark screen Includes one rigid spark screen AC01308 Rafter protector kit Includes four rafter protectors as show...

Страница 51: ...equires that a special type of wood be used and positioned inside the firebox in a manner that does not represent the way the firebox volume would normally be utilized using seasoned cordwood The EPA...

Страница 52: ...CTION MATERIALS MATERIAL CONDUCTIVITY k PER INCH RESISTANCE R PER INCH THICKNESS Micore 160 0 39 2 54 Micore 300 0 49 2 06 Durock 1 92 0 52 Hardibacker 1 95 0 51 Hardibacker 500 2 3 0 44 Wonderboard 3...

Страница 53: ...lesale price of the replacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any...

Отзывы: