Page 30
Installation Manual - L48
ENGLISH
VENTING
4.2.2 For installation of the restrictor after the venting is installed
1. Remove (2) screws from each end of the flue baffle and set aside.
2. Insert the restrictor up into the flue collar and position it as shown.
3. Then, re-install the flue baffle.
N°1 REMOVE BAFFLE
TO INSTALL
FLUE RESTRICTOR
N°2 FLUE RESTRICTOR
N°4 REMOVE BAFFLE
TO INSTALL
FLUE RESTRICTOR
N°3 FLUE RESTRICTOR
4.3 Clearance to Combustibles
NOTICE:
Maintain one inch (1") of clearance around vertical vent pipe. For horizontal vent, maintain a
minimum 1 inch clearance to the bottom and sides of the vent, and 3 inch clearance to combustibles
above the vent pipe.
VENT PIPE
1” MINIMUM CLEARANCE AROUND
VERTICAL VENT PIPE