![Valcourt FG00001 Скачать руководство пользователя страница 13](http://html2.mh-extra.com/html/valcourt/fg00001/fg00001_installation-instructions-manual_3064204013.webp)
Page 13
Installation Manual - L48
ENGLISH
2.7 Specifications
Propane
Natural
Altitude (ft)
0 - 4,500
0 - 4,500
Max. Input (BTU/Hr)
34,000
38,000
Min. Input (BTU/Hr)
27,000
25,000
KWH (Max.)
11.13
9.95
KWH (Min.)
7.32
7.90
Maximum Gas Supply Pressures
(inches water column)
14.0
14.0
Minimum Gas Supply Pressures
(inches water column)
11.0
4.5
Manifold Gas Supply Pressures
(inches water column)
10.0
3.5
Burner orifice
50 DMS (1.95 mm)
31 DMS (3.50 mm)
Efficiency
60.06 %
61.77 %
Air Shutter Opening
Fully Open
1/16"
Gas Inlet Shut-off Valve (pipe)
1/2" NPT
1/2" NPT
Vent Size
5" x 8"
5" x 8"
Blower spec
120 V, 60 HZ, 50W, 1.9 A (MAX.),130 CFM
NOTICE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor
air shutter adjustments for optimum performance.