background image

5

Zone 6 Auxiliary – K6 Relay

The V-2006A/V-2006AHF contains an auxiliary set of
make/break contacts which can be used to operate
mute contacts on a high powered amplifier or other
peripheral devices.  Zone 6 dry contact closure
operates when Zone 6 is activated alone or in together
with a group call or all call.  The contacts are rated at
1A @ 125 VAC or 2A @ 30VDC.

PRECAUTIONARY
DESIGNATIONS

CAUTION:  To reduce the risk of electric shock,

Do not remove cover.

No user serviceable parts inside.

Refer servicing to qualified service personnel.

This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.

This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 

Connect cord set to unit via IEC 320 female

connector located on one end of cord set to IEC
320 male appliance coupler located on the
V-2006A.

 

For 115 VAC

 use, verify fuse rating of 2 Amp

and voltage selector switch displays 115VAC.

 

For 230 VAC

 use, verify the fuse rating of 1

Amp and voltage selector switch displays 230VAC.

 

After all required connections have been

made, plug the cord set into appropriate AC wall
outlet.

TECHNICAL ASSISTANCE

Assistance in troubleshooting is available from the
factory.  When calling, you should have a multimeter,
several clip leads, a spare telephone test set available
and call from the job site.  Call (540) 563-2000 and
press 1 for Technical Support or visit our website at
http://www.valcom.com.

The V-2006A contains no user serviceable parts and
is not field repairable.  A service facility is maintained
in Roanoke, VA.  Should repairs be necessary, attach
a tag to the unit clearly stating your company name,
address, phone number, contact person and the
nature of the problem.  Send the unit to:

Valcom, Inc.

Repair and Return Dept.

5614 Hollins Road

Roanoke, VA  24019-5056

Содержание V-2006A

Страница 1: ...tipo 2A 125V El fusible de 2A 125V podra ser remplazado por uno de 1A 250V si el selector de voltaje esta puesto en 230V No abres SPECIFICATIONS Purpose The V 2006A is an Integrated Six Zone Paging Co...

Страница 2: ...006A V 2006AHF units Features of the V 2006AHF 6 zones of handsfree talkback one way or mixed paging one handsfree output per zone Two volume controls for handsfree paging Page Phone to Speaker Receiv...

Страница 3: ...ing The V 2006A V 2006AHF was designed for wall or table mounting Secure unit to wall studs or suitable brace away from heat sources or strong magnetic fields motors fans power supplies etc with contr...

Страница 4: ...peakers One way amplified speakers may be connected to the handsfree output of a zone programmed for talkback to augment the page output on that zone NOTE Only talkback speakers are able to receive re...

Страница 5: ...female connector located on one end of cord set to IEC 320 male appliance coupler located on the V 2006A For 115 VAC use verify fuse rating of 2 Amp and voltage selector switch displays 115VAC For 230...

Страница 6: ...flashing PROGRAM TESTING INSTRUCTIONS 1 Connect a single line tone dial phone or butt set to the RJ11 jack J6 Program Jack 2 Go OFF HOOK all LEDs illuminate for 1 second and then extinguish Program t...

Страница 7: ...normal use and service for a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or refund of any such defective device within th...

Страница 8: ...ne 3 Handsfree Output Tip Zone 3 Handsfree Output Ring UNA Ringing UNA Closure Clock Closure AMPLIFIED VALCOM SPEAKER GND 24 VDC TIP RING GND 24 VDC TIP RING 24 VDC POWER SUPPLY VALCOM 45 ohm TALKBACK...

Страница 9: ...p Ground Start Trunk Page Port Up Up Up Down For Remote Door Unlock K5 NC Break K5 NO Make K5 COM Stationary Customer Provided Electric Strikeplate Solenoid Zone 6 Auxiliary Contact Closure K6 NC K6 N...

Отзывы: