background image

4

Connection of One-Way Amplified Speakers

See Figure 1, 66 Block Diagram.

NOTE:  The V-2006A/V-2006AHF provides external
power of 30 power units (1.5 Amps of -24VDC) to
operate amplified speaker assemblies.  Additional
power supplies are required for speakers using
power over the 30 power units.  When using
additional power supplies, make certain:

     1)  

The -24VDC outputs are not connected  to

 each 

other.

     2)

Each speaker is connected to only one
power source (talkback speakers do not
require power).

3) 

All power supply grounds are connected
to a copper cold water pipe earth ground.
The use of an electrical ground in place of
a direct cold water pipe ground may
introduce noise into the paging system.

Power Connections

The V-2006A/V-2006AHF is provided with a NEMA
 5-15 cord set.

V-2006A Volume Adjustments

There are three volume controls on the unit for
individual adjustment of:

• Background Music
• Tones
• All Call

Clockwise adjustment increases volume, counterclock-
wise decreases volume.

NOTE:  During initial set up, adjust individual
speaker volume controls to page level first, then
adjust volume on page unit to the desired level for
music and tones.

V-2006AHF Volume Adjustments

There are six volume controls on the V-2006AHF to
control the volume of the handsfree talkback outputs. 
They are:

 

Phone to Speaker (adjusts volume of a page from
phone)

 

Speaker to Phone (adjusts response volume from
speaker; should be turned as low as possible)

 

Page (adjusts volume Group Call on handsfree
outputs)

 All 

Call

 Background 

Music

 Tones

Refer to Figure 2 for location of the volume controls.

Connections for the V-2006AHF

The V-2006AHF is programmable on a per zone basis
for one-way or talkback communication.  A single
talkback zone may have both one-way

 

and talkback

speakers.  One-way amplified speakers may be
connected to the handsfree output of a zone
programmed for talkback to augment the page output

on that zone.

NOTE:  Only talkback speakers are able to receive
reply.

  

No more than two (2) 45-Ohm talkback

speakers should be connected to any talkback
zone.  Do not use 8 Ohm speakers.

Connection of Talkback Speakers
(V-2006AHF only)

See Figure 1, 66 Block Diagram.

OPTIONAL CONNECTIONS

Background Music Connections

Connect the low level (-10 to -18dBm, 8 to 600 Ohms)
output of music source the (W/G) and (G/W) terminals
of the cross connect block.  Adjust music volume (page
overrides music).

NOTE:  Failure to use a low level music source
could cause music crosstalk on zones not
receiving music and may override the mute of
music during page.

Time Clock Closure (Single Tone)
Connections

Time clock contact closure connects to - V/G, G/V.  
Time clock signaling will override page.

UNA Closure Connections

Telephone System Night Answer contact closure 
connects to - V/BR, BR/V.  This tone will override music
but is overridden by a page.

UNA Ringing Connections

90V Night Answer Ring connects to - V/S, S/V.  These
connections will activate a night ring tone.  Telephone
System standard ring voltage.  This tone will override
music but is overridden by page.

Override Connections

Page override can be activated by a vacant C. O. line
position, loop start or ground start trunk or dedicated
single line phone.  Connect telephone system override
via a telephone modular cord to override RJ11 jack (J5)
or Tip, Ring to the W/O, O/W terminals of the cross
connect 66 block.

Remote Door Unlock with Tone Dial
Telephone

 

– K5 Relay

See Figure 2.
Before connecting an electric strikeplate to the
V-2006A/V-2006AHF, consult the manufacturer's
instruction for the proper installation arrangement.  The
dry contact closure is operated by pressing the asterisk
(*) key on a tone dial telephone after a zone has been
accessed.  The contact is rated at 1A @ 125VAC or 2A
@ 30VDC.

Содержание V-2006A

Страница 1: ...tipo 2A 125V El fusible de 2A 125V podra ser remplazado por uno de 1A 250V si el selector de voltaje esta puesto en 230V No abres SPECIFICATIONS Purpose The V 2006A is an Integrated Six Zone Paging Co...

Страница 2: ...006A V 2006AHF units Features of the V 2006AHF 6 zones of handsfree talkback one way or mixed paging one handsfree output per zone Two volume controls for handsfree paging Page Phone to Speaker Receiv...

Страница 3: ...ing The V 2006A V 2006AHF was designed for wall or table mounting Secure unit to wall studs or suitable brace away from heat sources or strong magnetic fields motors fans power supplies etc with contr...

Страница 4: ...peakers One way amplified speakers may be connected to the handsfree output of a zone programmed for talkback to augment the page output on that zone NOTE Only talkback speakers are able to receive re...

Страница 5: ...female connector located on one end of cord set to IEC 320 male appliance coupler located on the V 2006A For 115 VAC use verify fuse rating of 2 Amp and voltage selector switch displays 115VAC For 230...

Страница 6: ...flashing PROGRAM TESTING INSTRUCTIONS 1 Connect a single line tone dial phone or butt set to the RJ11 jack J6 Program Jack 2 Go OFF HOOK all LEDs illuminate for 1 second and then extinguish Program t...

Страница 7: ...normal use and service for a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or refund of any such defective device within th...

Страница 8: ...ne 3 Handsfree Output Tip Zone 3 Handsfree Output Ring UNA Ringing UNA Closure Clock Closure AMPLIFIED VALCOM SPEAKER GND 24 VDC TIP RING GND 24 VDC TIP RING 24 VDC POWER SUPPLY VALCOM 45 ohm TALKBACK...

Страница 9: ...p Ground Start Trunk Page Port Up Up Up Down For Remote Door Unlock K5 NC Break K5 NO Make K5 COM Stationary Customer Provided Electric Strikeplate Solenoid Zone 6 Auxiliary Contact Closure K6 NC K6 N...