background image

2

Access Methods

 

Electronic Key System (C. O. Line Position)

 

PABX (Loop or Ground Start Trunk)

 

1A2 Key Systems (400 Type Line Card required)

 

600 Ohms Page port equipped with contact

    

   

closure and DTMF dialing capability

 

Dedicated single line telephone

Additional Equipment Required

 Backboard/mounting 

surface

 

25 pair cable with female connector on one end

 

One 66 split block

 Speakers

 

Cat 3 or Cat 5 twisted 2-pair cable
(for speaker connections)

Physical Description

The V-2006A and V-2006AHF are contained in single,
gray steel cases, which can be wall or shelf-mounted.

V-2006A:

10.90"H x 13.00"W x 2.70"D

(27.69cm H x 33.02cm W x 6.86cm D)

6.2 lbs. (2.81 kg)

V-2006AHF

                10.90"H x 13.00"W x 2.70"D

(27.69cm H x 33.02cm W x 6.86cm D)

7.5 lbs. (3.40 kg)

                 

Environment

Temperature:

+32 to +104° F

0 to +40° C

Humidity: 

0 to 85% non-precipitating

Features of the V-2006A

 

Time Clock & Night Ring Tones (single/warble)

 

Override Input (Trunk Port Access)

 

Two Auxiliary Contact Closures

 

Programmable per Zone

       -  Background Music
       -  Clock (single tone)
       -  Night Ring (warble tone)
       -  Group Calls
       -  All Call
       -  One-way/Talkback (V-2006AHF for Talkback)

 

Three group calls and one all call group

 

Volume Controls for:
-  Background Music (music mutes during page)
-  Clock and Night Ring Tones
-  All Call

 Switch 

selectable

-  Dial Tone
-  Ringback Tone
-  Loop or Ground Start

 

Battery Backup Input (for VPB-260 only)

 

Inhibit Option for “Meet Me” answer

 

Common all call link for up to  (10)  V-2006A/
V-2006AHF units

Features of the V-2006AHF

 

6 zones of handsfree talkback (one-way or

        mixed) paging (one handsfree output per zone)

 

Two volume controls for handsfree paging
Page (Phone to Speaker)
Receive (Speaker to Phone)

 Tone 

options

(dip-switch selectable on a  system basis):

1 - dial tone
2 - alert tone (ringback tone)
3 - repeated alert tone

SYSTEM OPERATION

DO NOT OPERATE UNIT WITH COVER
REMOVED!

 

To Access Paging/Override

:  Press CO line key,

dial trunk access code or access page port if
applicable

 

System Dial Tone

:  If so optioned (dip switch #1),

the V-2006A/V-2006AHF returns dial tone

 

Dialing Zones

:  Dial 1 to 6 for individual zones

 

Dialing All Call

:  Dial 0 for All Call

 

Dialing Groups

:  For Groups 1, 2 or 3 – dial 7, 8

or 9 respectively

 

Activating Make or Break Contact Closures

;

K5

:  After dialing any individual zone, press the

asterisk (*) once for 2.2 seconds of relay closure

K6

:  This closure activates as long as zone 6 is

active

 

Dialing Another Zone:  

Press pound (#) key to

return dial tone

 

Priority Sequence

1)  Time Clock Tone
2) Override 

Page

3)  All Call Link
4) Page
5) Warble 

Tone

6) Background 

Music

Background Music

Background music may be connected to control unit. 
Background music will mute in zone paged if the zone
is programmed for background music.

Page Override

Requires use of a second vacant C. O. line position or
vacant loop or ground start trunk port for access.

OPERATION

:  Press line key (electronic key system)

or dial trunk access code (PABX) for override access
(override busy tone will be heard).  Dial zone and make
announcement.  The unit will disconnect when you
hang up, re-establishing the overridden page.

Содержание V-2006A

Страница 1: ...tipo 2A 125V El fusible de 2A 125V podra ser remplazado por uno de 1A 250V si el selector de voltaje esta puesto en 230V No abres SPECIFICATIONS Purpose The V 2006A is an Integrated Six Zone Paging Co...

Страница 2: ...006A V 2006AHF units Features of the V 2006AHF 6 zones of handsfree talkback one way or mixed paging one handsfree output per zone Two volume controls for handsfree paging Page Phone to Speaker Receiv...

Страница 3: ...ing The V 2006A V 2006AHF was designed for wall or table mounting Secure unit to wall studs or suitable brace away from heat sources or strong magnetic fields motors fans power supplies etc with contr...

Страница 4: ...peakers One way amplified speakers may be connected to the handsfree output of a zone programmed for talkback to augment the page output on that zone NOTE Only talkback speakers are able to receive re...

Страница 5: ...female connector located on one end of cord set to IEC 320 male appliance coupler located on the V 2006A For 115 VAC use verify fuse rating of 2 Amp and voltage selector switch displays 115VAC For 230...

Страница 6: ...flashing PROGRAM TESTING INSTRUCTIONS 1 Connect a single line tone dial phone or butt set to the RJ11 jack J6 Program Jack 2 Go OFF HOOK all LEDs illuminate for 1 second and then extinguish Program t...

Страница 7: ...normal use and service for a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or refund of any such defective device within th...

Страница 8: ...ne 3 Handsfree Output Tip Zone 3 Handsfree Output Ring UNA Ringing UNA Closure Clock Closure AMPLIFIED VALCOM SPEAKER GND 24 VDC TIP RING GND 24 VDC TIP RING 24 VDC POWER SUPPLY VALCOM 45 ohm TALKBACK...

Страница 9: ...p Ground Start Trunk Page Port Up Up Up Down For Remote Door Unlock K5 NC Break K5 NO Make K5 COM Stationary Customer Provided Electric Strikeplate Solenoid Zone 6 Auxiliary Contact Closure K6 NC K6 N...

Отзывы: