947180
PROGRAMMING QUICK REFERENCE TABLE
Table 1.
System Configuration Options
Feature
Mode Option/
Verify
Dial
Listen
For
Choose Option
Listen For
Default
Reset to Factory Defaults
To Select
10
Double
Beep
Enter 25327 to reset.
Enter any invalid number
string to escape.
Triple Beeps
25327
(CLEAR)
Number of Zone Map Digits
To Select
To Verify
20
21
Double
Beep
3 (digits)
4 (digits)
Triple Beeps
2
Serial Port Bit Rate
To Select
To Verify
22
23
Double
Beep
0 – 300 bps
1 – 1200 bps
2 – 2400 bps
3 – 4800 bps
4 – 9600 bps
5 – 14400 bps
6 – 19200 bps
Triple Beeps
9600 bps
Dial Tone Detect
To Select
To Verify
24
25
Double
Beep
0 – Enable
1 – Inhibit
Triple Beeps
Enable
Connect Password
To Select
To Verify
30
31
Double
Beep
Enter Password, enter # to
terminate the string.
Triple Beeps
None
Programming Password
To Select
To Verify
32
33
Double
Beep
Enter Password, enter # to
terminate the string.
Triple Beeps
✱✱
Confirmation Tone
To Select
To Verify
40
41
Double
Beep
0 – Off
1 – On
Triple Beeps
On
Pre-Announcement Tone
To Select
To Verify
42
43
Double
Beep
0 – Off
1 – On
Triple Beeps
On
Talkback Warning Tones
To Select
To Verify
44
45
Double
Beep
0 – Off
1 – Initial
2 – Initial and 30 sec.
Triple Beeps
Initial and 30
sec.
VOX Timer Disconnect
To Select
To Verify
50
51
Double
Beep
Enter Duration
0 – Off
1 – 10 sec.
2 – 20 sec.
3 – 30 sec.
4 – 40 sec.
5 – 50 sec.
6 – 60 sec.
Triple Beeps
30 Sec.
Computer Monitor
To Select
To Verify
52
53
Double
Beep
0 – Computer Monitor
1 – Visual Display
Triple Beeps
Computer Monitor
Input Computer Monitor
To Select
To Verify
54
55
Double
Beep
0 – AA Off
1 – AA On
2 – T/R Off
3 – T/R On
4 – N.B. Off
5 – N.B. On
Triple Beeps
AA – Off
T/R – Off
N.B. – Off
Supervised Trunk Mode
To Select
To Verify
56
57
Double
Beep
0 – Off
1 – On
Triple Beeps
Off
Zone Microphone
To Select
To Verify
58
59
Double
Beep
0 – Off
1 – On
Triple Beeps
Off
NOTES:
Exit the programming mode by dialing #. The # key will terminate a digit string (i.e., Password string)