947180
Note:
Use ALIAS numbers, if optioned. Otherwise, use physical zone/group numbers.
3. Enter
0
for NO (Music Not Enabled) or
1
for YES (Music enabled)
Hear TRIPLE beeps.
4. To verify the status of Music Enable for a given zone, dial
7 5
and repeat steps 2 and 3 above.
7 6 SET TALKBACK ENABLE
This is a zone output parameter that enables talkback capability for a selected output zone or group. The
choice is YES/NO, with the default being set to NO.
All speakers in a zone or group will be active 2-way speakers if talkback has been enabled for a zone.
Repeat this procedure for each output zone or zone group that you wish to have talkback.
1. Dial
7 6
to select this option.
Hear a DOUBLE beep.
2. Enter the zone or group zone number.
Hear a DOUBLE beep.
3. Enter
0
for NO (Not Enabled) or
1
for YES (Enabled)
Hear TRIPLE beeps.
4. To verify the status of Talkback Enable for a given zone, dial and repeat steps 2 and 3 above.
Note:
Only 2 talkback speakers are recommended per zone.
7 8 SET NIGHT BELL ENABLE
This is an individual zone output parameter. The choice is YES/NO with the default being NO. With this
parameter set to YES, night bell will be sent to selected outputs whenever ring voltage is present on the
night bell input (from the PBX to the controller).
If a closure is required to trigger the night bell, then a zone will need to be configured as an input to send
night bell to designated zones when a closure is present. This is discussed in Steps 27 and 28, Tone
Selection and Tone Routing.
You will need to repeat this procedure for each output zone that you wish to receive the night bell signal.
1. Dial
7 8
to select this option.
Hear a DOUBLE beep.
2. Enter the zone or group zone number.
Hear a DOUBLE beep.
Note:
Use ALIAS numbers, if optioned. Otherwise, use physical zone/group numbers.
3. Enter
0
for NO (Not Enabled) or enter
1
for YES (Enabled)
Hear TRIPLE beeps.
4. To verify the status of Night Bell Enable for a given zone, dial
7 9
and repeat steps 2 and 3 above.