VALCOM ONE-WAY PAGING 

SYSTEM DESIGN/INFORMATION 

 

GENERAL 

These instructions provide the basic information 
required to properly install a One-Way paging 
system manufactured by Valcom, Inc.  Valcom 
One-Way Paging Equipment may be used with 
any 1A2, Electronic Key, PABX Telephone 
Systems, or with one or more dedicated single 
line telephone sets. 

 

SYSTEM OVERVIEW 

Purpose 

Provides telephone accessed single or multizone 
paging. 

 

Applications 

 

Electronic Key Systems 

 PABX 

 

Stand alone systems 

 1A2 

 

 

 VALCOM 
ONE-WAY 
CONTROL 
    UNIT 

 ONE-W AY 
 SPEAKER 
ASSEMBLY

POWER 
SUPPLY 

TELEPHONE 
   SYSTEM 

ONE-WAY PAGING SYSTEM BLOCK DIAGR AM

FIGURE 1 

 

Features 

 

1, 3, 6, 9, and 24 (expandable with V-2925A 
in 24 zone increments for up to 96) zone page 
control units available. 

 

One-way all call to all speakers available. 

 

Volume controls and amplifiers in each 
speaker. 

 

No high power amplifier required. 

 

Standard CAT 3, 5, 5E twisted pair cable 
(typically 22 or 24 AWG) is used for speakers. 

 

Existing twisted pair house cables / feed 
cables may be used without introducing 
crosstalk. 

 

See Multi-Path Information for systems up to 
360 zones. 

 

 

 

Access Methods 

 

Electronic Key System line button (C. O. 
circuit required). 

 

PABX loop trunk port (trunk circuit required). 

 

Page port (some with N.O. CC). 

 

Station level access available (with 
appropriate adapter). 

 

Stand alone with dedicated single line sets. 

 

1A2 line button (line card required on most 
units). 

 

Capacity 

 

All units are one talkpath and one link. 

 

V-1094A, 1 zone (page port access only). 

 

V-2000A, 1 zone with an integrated power 
supply, background music input. 

 

V-2001A, 1 zone with an integrated power 
supply, background music capabilities and 
override capabilities, and featuring two 
integrated tone generators for night ringing 
and time clock tones. 

 

V-2003A, 3 zones with all call, background 
music capabilities, override capabilities, two 
integrated tones for night ringing and time 
clock signaling plus integrated power supply. 

 

V-2006A, 6 zones with all call, up to 3 group 
calls, override capabilities, background music 
capabilities, two integrated tone generators 
for night ringing and time clock tones plus 
integrated power supply. 

 

V-2924A, 24 zones with all call, background 
music capabilities. 

 

V-9937, 1 zone, page port access. 

 

V-1109RTVA, 9 zones with all call, 
background music capabilities (no station or 
page port access). 

 

Each of the units listed above will drive up to 40 
Valcom one-way amplified speaker assemblies 
per zone (150 on V-1094A, V-9937, V-2000A, 
V-2001A, V-2003A and V-2006A).  Additional 
speakers may be added to a zone by using a 
V-1094A.  Each V-1094A allows the addition of 
150 more amplified speaker assemblies to that 
zone.

Содержание ONE-WAY PAGING SYSTEM

Страница 1: ...required Page port some with N O CC Station level access available with appropriate adapter Stand alone with dedicated single line sets 1A2 line button line card required on most units Capacity All un...

Страница 2: ...9 D 27 7cm x 33 0cm x 6 83cm V 2924A 17 5 H x 10 3 W x 3 06 D 44 45cm x 26 26cm x 7 77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2...

Страница 3: ...any of the following 1 zone V 2000A 1 zone V 2001A 3 zones w all call V 2003A 6 zones w all call V 2006A 9 zones w all call V 1109RTVA 24 zones w all call V 2924A 24 zone expansion module up to 96 tot...

Страница 4: ...one page units may not be used on page port output The V 2003A and V 2006A may be used on certain page ports that have an associated page port contact closure and support DTMF signaling Station level...

Страница 5: ...f Connections to a Valcom Page Control Interface Your Telephone or Telephone System SYSTEM INSTALLATION General These instructions will provide a basic understanding for wiring Valcom one way paging e...

Страница 6: ...g areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very difficult...

Страница 7: ...peaker amplifier and volume control in a suitable baffle or housing The speakers and control units require a 24VDC power supply 48VDC for the V 1038 to operate Connections from the control unit to the...

Страница 8: ...the microphone offensive feedback cannot occur The Stacking Feedback Eliminator V 9964 can control up to 150 amplified speakers or horns in a single zone The Stacking Feedback Eliminator V 9964 can be...

Страница 9: ...elephone cable versus installing both telephone cable and 70 volt shielded paging cable Unlimited one way speaker expansion since each speaker is self amplified Jobs requiring explosion proof systems...

Страница 10: ...9915 5 Backbox are made of Borg Warner Flamex fire retardant 94 0 material and may only be ordered in multiples of five 5 The V 9904M 5 V 9914M 5 and V 9915M 5 metal bridges and backboxes may only be...

Страница 11: ...20 20 30 6 0 Background Music X X X X X X All Call X X X X Night Ringing Tones X X X Note 1 X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input...