6.3.5. REPLACING THE PROBE AND CARTRIDGE HEATERS
The steps for replacing the cartridge heaters and temperature probe are described
below.
Before repairing the element, clean the outside to prevent adhesive from getting
into the electric box.
1. Release the screws on the electric box cover.
2. Remove the element to be replaced (probe or resistor).
3. Release the element from the ceramic strip or terminal.
4. Peel the 15 mm wire tips.
5. Connect the element to the ceramic strip or terminal.
6. Insert the replaced part into the hole and close the cover.
7. Re-connect the electricity from the gun to the hose.