MUS0920201
07/10/2014 29
MELTON, S.L.U. - POLIGONO INDUSTRIAL AGUSTINOS CALLE G-34,31160 ORCOYEN, NAVARRA
TEL: 00 34 948 321580 Fax: 00 34 948 326584 e-mail: [email protected]
4.3.2 SYSTEM SETTINGS.
You can access this feature via the settings / system menu.
4.3.2.1 Language:
It is found under the settings / system / language menu.
Use the +/- keys to choose a language.
4.3.2.2. Temperature Units:
This is found under the settings / system / temperature units menu.
You may choose Celsius (ºC) or Fahrenheit (ºF):
4.3.2.3. Pump Temperature and System Read Programming
This is found under the settings / system / pump and system ready menu.
You must enter a small gap between the programmed operating temperature for
the zones and the real temperature at which the system will be considered ready.
It’s related to the temperature established for each zone. The system indicates it is
ready (and the System Ready LED turns green). The system provides permission when
each zone reaches the programmed temperature. The permission activates the pump.
This prevents the pump from activating before the adhesive melts.
See the adhesive technical data sheet to find the melting point.
The pre-programmed temperature must be set to at least -5ºF (-3ºC). If set very
close to the point (-1°F, for example), the pump will repeatedly stop due to small
temperature fluctuations.
The parameter range goes from 0ºF to 36ºF (0ºC to 20ºC) and the manufacturer
preset value is 5ºF (3ºC).