4.3.11. ENCODER:
Use the left/right keys to configure the encoder settings:
Use the +/- keys to configure the measurement units:
4.3.12. TEMP:
This is found under the settings / temp. menu.
The parameters P I D S R can be configured for each zone in order to optimise the
heating in each zone.
Press the +/- and right/left keys to select the zone and parameter you wish to
modify.
Press the left key just after entering the Temp menu to directly access the
AutoTune option. Press Start to activate Auto Tuning.
The AutoTune feature is generally used once when commissioning the machine.
When all of the hoses and guns are connected to the machine, AutoTune is activated
which identifies the active zones and automatically adjusts the P I D S R parameters so
the active heating zones operate best. This function may take at least 8 hours to
complete and the machine cannot be disconnected from the power source until it is
finished.
You can access this parameter with a password level of 3 or higher.