Rev. 1.1
7.Control with External Signals
CAUTION
Use output signal cable of 3m or shorter.
Do not apply too high current and voltage.
Do not use external connector except SELV circuit with reinforced insulation or a
circuit with double insulation.
Connector
Communications Specifications
No.
Signal
1
Tx
2
Rx
3
NC
4
GND
Command Formats
Channel Specification
Channel
CH1
CH2
CH3
CH4
Set Value
00
01
02
03
Lighting Mode Setting
40μS
80μS 120μS 200μS 600μS 1.2mS
4mS
10mS
20mS
40mS
Channel
F01
F02
F03
F04
F05
F06
F07
F08
F09
F10
Set Value
01
02
03
04
05
06
07
08
09
10
Status
Strobe Mode
Receive Data
Light Intensity Setting
Lighting Mode Setting
ON/OFF Setting
ID
specification
00 (Fixed)
Checksum
00 to FF
(Refer to
Checksum)
<CR><LF>
Delimiter
O
N
NG
01: Command Error
02: Checksum Error
03: Setvalue out of Range Error
Receive Command
OK
-----
Function
Header Channel specification
@
00 to 03
(Refer toChannel
Specification)
FF: All channels
(ON/OFF setting only)
Channel Specification
Channel
CH1
CH2
CH3
CH4
Set Value
00
01
02
03
Checksum
Header Channel
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
Character
@
0
1
F
1
2
5
0
0
ASCII (hexadecimal) 40 hex 30 hex 31 hex 46 hex 31 hex 32 hex 35 hex 30 hex 30 hex 1DF hex
*Set value that are higher than 10 are not valid.
The codes of the ASCII characters
from the header to the ID are
added,
the lowest byte is converted to
hexadecimal, and two characters are
sent.
Example: Setting the Light Intensity of Channel 2 10 125
Sent command
ID
Total
Send Data (*1)
Instruction
Data (*2)
Light Intensity Setting
F
000 to 255 (000:Min. Intensity, 255:Max. Intensity)
000
Lighting Mode Setting
S
01 to 10 (Refer to Lighting Mode Settings)
00
ON/OFF Setting (*3)
L
0 : Not Lit , 1 : Lit (*4)
-----
(*5)
*1: Send a data within 4 seconds from 'Header' to 'Delimiter', otherwise time-out error occurs and command data will be rejected.
*2: Specify all numbers in Decimal format.
*3: ON/OFF settings from EIA-232-D communications without regards to trigger logic switch, turned OFF at '0' and ON at '1'. ON/OFF setting will not be held after turning
the power off.
*4: When operating EIA-232-D Communications and trigger signal input at same time in ON/OFF mode.
When Trigger logic switach is at H : if either controls setting, Light unit will be turned OFF.
When Trigger logic switach is at L : if either controls setting, Light unit will be turned ON.
*5: Defalt setting for trigger logic switch is H ='1(ON)' and L='0(OFF)'.
Default
00 (Fixed)
ID
specification
Checksum
Delimiter
00 to FF
(Refer to
Checksum)
<CR><LF>
Sent command
@
Function
Header
Channel specification
00 to 03
(Refer toChannel
Specification)
FF: All channels
(ON/OFF setting only)
Communications protocol
EIA-232-D
Baud rate
38,400 bps
Data bit length
8 bits
Parity bit
None
Stop bits
1 bit