VAL VLP-2430-4 Скачать руководство пользователя страница 3

Rev. 1.1 

3.Confirming package contents 

Item 

Q’ty 

Main unit 

AC power cord 

*Use appropriate AC power cord conforming to the standards in the country or region where this product used. 

(Optional) 

Ferrite core clamp filter for AC power cord 

*Applicable cable outer diameter 6 to 9mm. 
*Attach to AC power cord within 100mm from unit.

 

This operation manual 

 

4.Specification 

Model 

VLP-2430-4 

VLP-2460-4 

Input Voltage 

AC 100  –  240V (rated)  ±10%    50/60Hz 

Power Consumption 

AC100V/1A – AC240V/0.5A 

Inrush Current(A)      30/60 (AC115/230V) at cold start 

AC Power Cord 

3m (max.) cord with a protective earth terminal 

Rated output voltage 

4 Channels  DC24V (between output and GND) 

Rated output current 

1.1A (Total for 4 channels) 

2.2A (Total for 4 channels) 

Input Connectors 

AC input 3-pin inlet EN 60320-1 certified C14 type x 1 

Output Connectors 

SMP-03V-BC(JST)  1:output+  2:NC    3:output- 

Insulation resistance:500MΩ(min.)  Withstand voltage:AC1500V/minute 

External control connectors 

Trigger input MIL connector (MIL-C-83503 compliant), 10-pole 

For setting the light intensity and lighting mode: e-CON 3-pole 

Intensity Control 

INT.: Control manually by volume knobs 

EXT.: Remote control by external EIA-232-D 

Strobe Control 

NOR.: The lights are always ON. 

STR.: Strobe control. 

Lighting method 

PWM (100KHz)   

Overcurrent protection 

Operates at 105% or higher of the rated current 

Insulation resistance/ withstand 

voltage 

Between input and FG (frame ground): AC1500V /minute (10mA), DC500V 50MΩ  (min.) 

Operating Environment 

Temperature:  0 to 40℃    Humidity:  20~85% RH without condensation 

Altitude:  2000m Max.    Pollution level:  2 

Protective ground classⅠ  Installation category  Ⅱ(restricted to use in indoor 

environment) 

Storage Temperature/ Humidity 

-15 to 40℃/20 to 85% RH without condensation 

Cooling Method 

Natural air cooling 

Dimensions 

W120mm x D88mm x H126.5mm 

Weight 

Approx. 930g 

Environmental regulations 

RoHS compliant 

European Standards 

(CE Marking) *Under processing 

EN61326-1 

EN61010-1 

Содержание VLP-2430-4

Страница 1: ...e and safety please read this manual thoroughly before starting operation Keep this manual for the whole product lifetime The following warning symbols are used in this manual Be sure to fully understand the contents WARNING A warning denotes a hazard that can cause severe injury or death CAUTION A caution denotes a hazard that can cause injury or damage of equipment ...

Страница 2: ...ON 1 USE the extension or remote cables 3m maximum to prevent power drop by voltage reduction or malfunction by noise 2 Installation of the product 1 Place horizontally in a well ventilated space on the rubber feet at the bottom of the unit 2 Do not topple or lay on its side 3 Do not put on unstable or vibrational place 4 Do not use in environment with humidity dusty high temperature or fire 5 Kee...

Страница 3: ...ation resistance 500MΩ min Withstand voltage AC1500V minute External control connectors Trigger input MIL connector MIL C 83503 compliant 10 pole For setting the light intensity and lighting mode e CON 3 pole Intensity Control INT Control manually by volume knobs EXT Remote control by external EIA 232 D Strobe Control NOR The lights are always ON STR Strobe control Lighting method PWM 100KHz Overc...

Страница 4: ... for Light Unit connected to output connector CH3 CH4 lit Lit when changing settings for Light Unit connected to output connector CH4 Internal External Mode Selector Selects internal INT or external EXT control mode Normal Strobe Mode Selector Selects normal NOR or strobe STR control mode Trigger Logic Switch Selects the logic of the trigger signal External Control Connector For external control w...

Страница 5: ...nel is set at INT 4 Remote control When the Remote control switch on front panel is set at EXT external control input signal is available through RS 232C or TRIG IN connector on front panel 5 On Off Control It is possible to turn off the light by inputting off signal by remote control mode 6 Error Signal Error indicator on front panel will be on if an error of LED lighting unit detected such as br...

Страница 6: ...not valid The codes of the ASCII characters from the header to the ID are added the lowest byte is converted to hexadecimal and two characters are sent Example Setting the Light Intensity of Channel 2 10 125 Sent command ID Total Send Data 1 Instruction Data 2 Light Intensity Setting F 000 to 255 000 Min Intensity 255 Max Intensity 000 Lighting Mode Setting S 01 to 10 Refer to Lighting Mode Settin...

Страница 7: ...01N0300B3CRLF Setting the Lighting Mode Specify the ID and channel and set the lighting mode Setting example Send data Receive data When ON Receive data When NG Setting the lighting mode to Strobe Mode at 200μs for CH2 of the VLP 2430 4 that the ID set to 00 00S0400B8CRLF 00O0050CRLF 00N0300B2CRLF To set ON OFF Signal in ON OFF mode Specify the ID and the channel and set ON OFF signal Setting exam...

Страница 8: ...l be turned ON Connector Layout External Trigger Input Connector Plug External Trigger Signal Connection Example Signal Specifications Rated input voltage Maximum input voltage ON voltage ON current OFF voltage OFF current ON OFF response time Input impedance 24 VDC 26 4 VDC 14 4 VDC min 3 mA max 5 VDC max 1 mA max 10 μs max 7 5kΩ per terminal TRIG IN 1 2 3 10 5 7 9 4 6 8 External Circuits VLP 243...

Страница 9: ... trigger signal input Strobe Mode The Light Units are turned ON for the set time after the external trigger signal input Trigger Input Sequence Diagram A pulse width of ON signal shall be 10μs or more The Light Units will be turned on for at least 40μs even when the input ON signal is less than 40μs If another trigger is input before the Light Units turns OFF in Strobe Mode the starting point of t...

Страница 10: ...e performance specifications etc by customers after the day of product delivery Faults or damage that occur due to use of the product other than for its designed purpose Faults or damage that occur due to natural or human causes such as saltwater air damage gas damage earthquakes floods fire lighting or armed conflicts Disclaimer VS Technology Thailand Co Ltd shall not be responsible for any appen...