User’s Guide ______________________________________________________________________
68 ___________________________________________________________________M210925EN-B
Combined Data Message (aR)
With this command you can request all individual messages
aR1
and
aR5
with just one command.
Command format:
aR<cr><lf>
Example of the response:
0R1,Dm=027D,Sm=0.1M<cr><lf>
0R5,Th=76.1F,Vh=11.5N,Vs=11.5V,Vr=3.510V,Id=HEL__<cr><lf>
Composite Data Message Query
(aR0)
This command is used to request a combined data message with user
configurable set of wind and supervisor data.
Command format:
aR0<cr><lf>
Example of the response (the parameters included can be chosen
from the full parameter set of the commands aR1 and aR5):
0R0,Dx=005D,Sx=2.8M,Th=23.6C<cr><lf>
For selecting the parameter set in the response message, see
Chapter 8,
Sensor and Data Message Settings, on page 95
.
where
a
=
Device address (default = 0)
R
=
Combined message query command
<cr><lf>
=
Command terminator
where
a
=
Device address
R0
=
Composite data message query command
<cr><lf>
=
Command terminator