Chapter 6 ________________________________________________________ Connection Options
VAISALA_______________________________________________________________________ 57
Setting Fields
a
=
Device address
XU
=
Device settings command in ASCII and NMEA 0183
XXU
=
Device settings command in SDI-12
[A]
=
Address: 0 (default) ... 9, A ... Z, a ... z
[M]
=
Communication protocol:
A = ASCII, automatic
a = ASCII, automatic with CRC
P = ASCII, polled
p = ASCII, polled, with CRC
N = NMEA 0183 v3.0, automatic
Q = NMEA 0183 v3.0, query (= polled)
S = SDI-12 v1.3
R = SDI-12 v1.3 continuous measurement
[T]
=
Test parameter (for testing use only)
[C]
=
Automatic repeat interval for the Composite
Message: 0 ... 3600 s (0 = no automatic repeat). Does
not work in SDI-12 modes.
[I]
=
Serial interface: 1 = SDI-12, 2 = RS-232, 3= RS-485,
4 = RS-422
[B]
=
Baud rate: 1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200
[D]
=
Data bits: 7/8
[P]
=
Parity: O = Odd, E = Even, N = None
[S]
=
Stop bits: 1/2
[L]
=
RS-485 line delay: 0 ... 10000 ms
Defines the delay between the last character of the
query and the first character of the response message
from WMT52. During the delay, the WMT52's
transmitter is disabled. Effective in ASCII, polled
and NMEA 0183 query protocols. Effective when
RS-485 is selected (C = 3).
[N]
=
Name of the device: WMT52 (read only)
[V]
=
Software version: for example, 1.00 (read only)
<cr><lf>
=
Response terminator