3.7 Configuration
WAC155 default settings are suitable for Vaisala Anemometer WAA151 and Vaisala Wind Vane
WAV151. No configuration is needed.
If you have WA25 wind sensors, you must configure WAC155. See
.
3.7.1 Configuring WAC155 for WA25
You must configure WAC155 for WA25. With default settings WAC155 and WA25 sensors can
return null fields.
Type commands on a single line and terminate them with a line feed <lf> or a
carriage return <cr> character. Separate parameters and values by a space.
1. Open a serial connection to WAC155. The default settings are
9600 bps, 8 N 1
.
2. To open a connection for commands, type
OPEN
[
id
]
<cr>
.
open $
3. To set the
spdvoltlimit
parameter, type
SETALR
spdvoltlimit
0
.
4. To set the
dirvoltlimit
parameter, type
SETALR
dirvoltlimit
0
.
5. To set the
powersave
parameter, type
SETMEA
powersave
0
.
6. To get the parameters into use, reset WAC155 by typing
RESET
.