OPERATION

Remove the PTB220TS from the package and connect a wall adapter to
recharge the battery. Switch the power on. The barometer is now ready
for use. For detailed operation instructions and descriptions refer to the
User's Guide of the PTB220 series digital barometers.

NOTE

The pressure port is closed, if the pressure connector is detached. For
measurement, the connector 

MUST

 be on place.

Operating voltage

DC voltage of 10...25 VDC is required to operate the barometer. A
power cord with a suitable plug-in connector is supplied with the
PTB220TS for use with a local power source. It is very important to
observe the polarity of the DC supply voltage.

NOTE

Negative terminal is in the center.

If the wall adapter is used, the barometer will operate from the mains
and at the same time recharge the internal lead battery of the
PTB220TS. If no adapter is used the PTB220 barometer will operate
using the internal lead battery.

F

IGURE 

1

Back plate of the PTB220TS tilting frame

Содержание PTB220TS / CASE

Страница 1: ...PTB220TS CASE USER S GUIDE U370EN 1 1 JUNE 1999...

Страница 2: ...may be reproduced in any form or by any means electronic or mechanical including photocopying nor may its contents be communicated to a third party without prior written permission of the copyright ho...

Страница 3: ...1 OPERATION 2 Operating voltage 2 Tilting frame 3 Battery 3 RS232 3 RS485 4 LED Indicators 4 ASSEMBLING THE CASE AND AN EXISTING BAROMETER 5 TECHNICAL DATA 7 Electronics 7 Electromagnetic compatibilit...

Страница 4: ...essure transducers class A accuracy local display RS232 485 serial interface This guide gives the basic operating instructions of the PTB220TS It does not however replace the operating manual of the P...

Страница 5: ...closed if the pressure connector is detached For measurement the connector MUST be on place Operating voltage DC voltage of 10 25 VDC is required to operate the barometer A power cord with a suitable...

Страница 6: ...removed from the case by lifting upwards NOTE The pressure connector has to be removed before closing the wooden carrying case Battery The battery gives a twelve hour service period The period is even...

Страница 7: ...r of the PTB220TS CASE is as following PIN SIGNAL 1 not used 2 RS485 HI 3 not used 4 not used 5 RS485 LO 6 not used LED Indicators There are four LED indicators in the back plate of the tilting frame...

Страница 8: ...asily be detached after the barometer is installed into the case 1 Remove the wooden tilting frame from the case 2 Unscrew the base plate 3 Attach the PTB220 onto the base with four M6x16 screws 4 Thr...

Страница 9: ...ering Place the conducting wire end to left hand side 9 Attach the spacers 2 pcs M3x12 Fix the support bar of the pressure port to the spacers 10 Attach the M3x18 spacers 4 pcs 11 Connect the flat cab...

Страница 10: ...f duplex RS485 half duplex Connectors 9 pin female sub D connector 6 pin 5 mm screw terminal bus Electromagnetic compatibility PTB220TS CASE with the PTB220 barometer is fully compatible according to...