background image

en

2.10 

Installing the photovoltaic module

2.10.1  Observing the clamping surface

b

a

6

a  clamping length at least 30 mm

b  clamping depth 3–7 mm

 

>

Ensure that the clamping length and depth on the PV 
module frame are sufficient.

2.10.2  Attaching the end/middle clamps

 

>

Observe the set-up instructions for the mounting frame 
and the end/middle clamps (

¬

 image 

3

).

Electrical installation

Only qualified electricians may carry out the electrical instal-
lation.

3.1 

Preparing the electrical installation

 

>

Calculate the maximum number of photovoltaic modules 
connected in series and/or parallel (

6

, image 

2

) in 

accordance with the maximum permissible system volt-
age and reverse current capacity (

¬

 page 

6

), and create 

a wiring plan.

i

Note

Under expected operational conditions, a photo-
voltaic module can provide a greater current and/

or a greater voltage than would be stated in the standard-
ised test conditions. Multiply the values of I

sc

 and V

oc

 stated 

on the module by a factor of 1.25 to dimension the compo-
nents provided in the installation.

 

>

Check whether overvoltage and lightning protection is 
required and whether there is an overvoltage and light-
ning protection concept that is complies with the relevant 
regulations.

 

>

If a generator connection box is integrated into the sys-
tem, check whether string diodes are required.

Cabling the photovoltaic module

 

>

Protect the cable against direct sunlight and high tensile 
loading.

 

>

Route the cabling behind the photovoltaic module, if pos-
sible so that it is below the frame.

 

>

If extension cables (

8

, image 

2

) are required, use only 

suitable cables and observe the instructions for the plug 
connectors.

 

>

Position the connector boxes (

2

, image 

1

), as shown in 

image 

9

.

3.2 

Carrying out the electrical installation

 

>

Carry out the electrical installation based on the wiring 
plans.

 

>

Install suitable overvoltage and lightning protection, if 
required or stipulated.

 

>

Install module string/bypass diodes, if required, and the 
required overcurrent protection.

3.3 

Cabling requirements

 

No plasticisers

 

UV-resistant

 

Performance-related cross-section (

³

 4 mm

2

)

 

Temperature range: - 40 °C…+ 120 °C

 

MC4 plug connections (

5

, image 

2

)

3.4 

Series circuit

 

>

Wire several photovoltaic modules in series; schematic 
diagram (

¬

 image 

4

).

 

>

Avoid a ring main (

¬

 image 

5

).

3.5 

Requirements for inverters and earthing

 

>

Observe the installation instructions for the inverter (

7

image 

2

).

 

>

Check whether local regulations stipulate protective 
earthing (

9

, image 

2

).

 

>

With the protective earthing, establish a secure electrical 
connection between the PV module frame and the earth 
potential or the earthed mounting frame.

 

>

If required, install lightning protection in addition to the 
protective earthing.

 

>

Never use the PV module frames or their protective 
earthing as active components of the lightning protection.

 

>

Use separate arresters for connecting the lightning 
arrester to the lightning protective earth.

 

>

Always have competent persons plan and install the out-
door and, if required, indoor lightning protection.

 

>

When directly installing it on the PV module frame, use 
suitable materials that do not encourage electrical corro-
sion.

Start-up

 

>

Observe the installation instructions for the inverter.

Handing over to the operator

 

>

Hand all of the documents over to the end user.

 

>

Inform them how they should respond if faults and dam-
age occur, and about the maintenance and inspection 
intervals.

Troubleshooting

6.1 

Eliminating faults

 

>

Observe the instructions for the inverter.

6.2 

Procuring spare parts

The original components of the product were also certified 
by the manufacturer as part of the declaration of conformity. 
If you use other, non-certified or unauthorised parts during 
maintenance or repair work, this may void the conformity of 
the product and it will therefore no longer comply with the 
applicable standards.
We strongly recommend that you use original spare parts 
from the manufacturer as this guarantees fault-free and safe 
operation of the product. To receive information about the 
available original spare parts, contact the contact address 
provided on the reverse of these instructions.

 

>

If you require spare parts for maintenance or repair work, 
use only the spare parts that are permitted for the prod-
uct.

 

Installation and maintenance instructions

0020273012_00

5

Содержание VPV P 290/2 M SWF

Страница 1: ...SWF 0020273300 VPV P 300 2 M BBF 0020273299 VPV P 305 2 M BWF 0020273298 2 1 4 3 1 6 7 5 8 9 2 3 4 5 VPV P en Operating installation and maintenance instructions es Instrucciones de funcionamiento in...

Страница 2: ...not carried out at all Have faults and damage eliminated immediately Adhere to the maintenance intervals specified Risk of death caused by missing fall protection Secure people and material against f...

Страница 3: ...n W and measurement accuracy toler ance in VMPP Nominal voltage in V IMPP Nominal current in A VOC No load voltage in V ISC Short circuit current in A max Usyst Maximum system voltage in V STC Standar...

Страница 4: ...and soft gloves Do not exert tension or pressure on the connection boxes or the cabling 2 2 Storing the photovoltaic module Always store the photovoltaic module in a dry padded location Always store t...

Страница 5: ...tant Performance related cross section 4 mm2 Temperature range 40 C 120 C MC4 plug connections 5 image 2 3 4 Series circuit Wire several photovoltaic modules in series schematic diagram image 4 Avoid...

Страница 6: ...ominal output Pnom 290 W 300 W 305 W Voltage at Pmax Umpp 31 3 V 31 2 V 31 4 V Current at Pmax Impp 9 25 A 9 63 A 9 72 A Short circuit current Isc 9 80 A 9 97 A 10 06 A No load voltage Voc 39 3 V 39 4...

Страница 7: ...s materiales por la realizaci n incorrecta de los trabajos de mantenimiento y reparaci n o por su omisi n Encargue la eliminaci n inmediata de aver as y da os Respetar los intervalos de mantenimiento...

Страница 8: ...dulos fotovoltaicos v ase la portada 3 1 Datos en la placa de caracter sticas Dato Significado VPV P 2 Denominaci n de tipo PMPP Potencia calor fica nominal en W con toleran cia de la clasificaci n en...

Страница 9: ...los bordes y las esquinas de las placas de cristal Transporte el m dulo fotovoltaico en posici n vertical El m dulo fotovoltaico debe trasladarse entre dos perso nas sujetando por los laterales largos...

Страница 10: ...ecci n contra sobreintensidad requerida 3 3 Requisitos para el cableado Sin plastificante Resistente a los rayos UV Secci n transversal con la potencia adecuada 4 mm2 Rango de temperatura 40 C 120 C C...

Страница 11: ...instalaci n el ctrica y para el montaje 9 Datos t cnicos VPV P 290 2 M SWF VPV P 300 2 M BBF VPV P 305 2 M BWF Potencia calor fica nominal Pnenn 290 W 300 W 305 W Tensi n a Pmax Umpp 31 3 V 31 2 V 31...

Страница 12: ...out moment Tenez vous distance des composants conducteurs Risques de blessures et de dommages mat riels en cas de maintenance ou de r paration n glig e ou non conforme En pr sence d anomalies de fonct...

Страница 13: ...ig neusement cette notice ainsi que tous les autres docu ments compl mentaires applicables pour pouvoir vous y r f rer ult rieurement 3 Description du produit Composition du produit vue d ensemble de...

Страница 14: ...pointu ou tranchant 2 4 Contr le du contenu de la livraison Quantit D signation 1 Module photovolta que 1 Lot de documentation 2 5 Contr le du ch ssis de montage V rifiez que le ch ssis de montage a b...

Страница 15: ...hotovolta ques comme dans le sch ma illustration 4 vitez le montage en boucle illustration 5 3 5 Exigences relatives l onduleur et la mise la terre Reportez vous la notice d installation de l onduleur...

Страница 16: ...p 990 x 1660 x 35 mm 990 x 1660 x 42 mm 990 x 1660 x 42 mm Hauteur du cadre 35 mm 42 mm Poids 19 kg Mat riau du cadre Al Raccordements Bo tier de raccordement 2 illustra tion 2 avec 3 diodes bypass c...

Страница 17: ...t fall 1 4 Generelle sikkerhetsanvisninger for installat rer Fare p grunn av utilstrekkelige kvalifikasjoner Alt arbeid som er beskrevet i installasjons og vedlikeholds anvisningen m kun utf res av in...

Страница 18: ...n Ser No For identifikasjon VDE kontrolltegn 3 2 Serienummer Serienummeret er angitt p et skilt p siden p produktet og p et skilt ved siden av typeskiltet 1 bilde 1 3 3 CE merkingng CE merkingen dokum...

Страница 19: ...komponenter 2 10 Montering av solcellemodulen 2 10 1 V r oppmerksom p klemmeflaten b a 6 a Klemmelengde minst 30 mm b Klemmedybde 3 7 mm S rg for tilstrekkelig stor klemmelengde og klem medybde p sol...

Страница 20: ...du utelukkende bruke reservedeler som er god kjent for produktet 6 3 Reparasjoner Ta hele solcelleanlegget midlertidig ut av drift side 18 f r Skift ut defekte komponenter Ikke utf r reparasjoner i k...

Страница 21: ...lassifisert for bruksklasse A i henhold til IEC 61730 De elektriske effektdataene finner du i databla det eller p typeskiltet 10 Inspeksjons og vedlikeholdsarbeid oversikt Tabellen nedenfor inneholder...

Страница 22: ...a a 22 0020273012_00 1 1 1 3 4 1 2 IP 1 3 1 4 1 5...

Страница 23: ...ar 0020273012_00 23 2 2 1 2 2 3 3 1 VPV P 2 PMPP VMPP IMPP VOC ISC max Usyst STC IR IP 67 II class C Control No Ser No VDE 3 2 1 1 CE 3 3 4 5 5 1 23 5 2 5 3 6 6 1 7 8 Country Specifics...

Страница 24: ...24 0020273012_00 1 2 2 1 2 2 2 4 1 1 2 5 9 7 8 2 6 A 2 7 A 2 8 24 2 9 2 10 2 10 1 b a 6 7 3 b 30 a 2 10 2 3 3 3 1 6 2 25 i Isc 1 25 Voc 2 8 9 1 2 3 2 3 3 2 4 120 40 2 5 MC4 3 4 4 5 3 5 2 7 2 9...

Страница 25: ...Pmax Umpp 9 72 A 9 63 A 9 25 A Pmax Impp 10 06 A 9 97 A 9 80 A Isc 39 6 V 39 4 V 39 3 V Voc 990 x 1660 x 42 mm 990 x 1660 x 42 mm 990 x 1660 x 35 mm x x 42 mm 35 mm 19 kg Al 2 2 2 4 1200 MC4 3 800 2 4...

Страница 26: ...00 200 II 430 430 200 200 430 430 b c a 1 2 III 120 120 310 310 3 200 200 3 IV 210 210 140 140 3 200 200 3 a a a 250 40 3 4 V a a a 250 40 3 4 42 mm Product with 42 mm frame Producto con marco de 42 m...

Страница 27: ...IV Pressure up to 5400 Pa approx 540 kg m suction up to 2400 Pa approx 240 kg m Nivel de carga IV pre si n hasta 5400 Pa aprox 540 kg m succi n hasta 2400 Pa aprox 240 kg m Niveau de charge IV pressio...

Страница 28: ...28 0020273012_00 9...

Страница 29: ...nte Pol Industrial Apartado 1 143 C La Granja 26 28108 Alcobendas Madrid Tel fono 9 02116819 Fax 9 16615197 www vaillant es 3 GB United Kingdom Vaillant Ltd Nottingham Road Belper Derbyshire DE56 1JT...

Страница 30: ......

Страница 31: ......

Страница 32: ...3012_00 EGESGBNOTN 032018 Subject to technical modi cations Reservado el derecho a introducir modi caciones t cnicas Sous r serve de modi cations techniques Med forbehold om tekniske endringer 0020273...

Отзывы: